HYBRID CONTROL SYSTEM, Diagnostic DTC:P0AE2-773

DTC Code DTC Name
P0AE2-773 Hybrid Battery Precharge Contactor Circuit Stuck Closed

DESCRIPTION

Refer to the description for DTC P0AE6-225 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0AE2 773 SMRP on the HV battery positive side stuck closed
  • Hybrid battery junction block assembly

  • Inverter with converter assembly

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 Click here.

INSPECTION PROCEDURE

CAUTION:


  • When troubleshooting P0AE2-773, be sure to wrap the tools with electrical tape. (It is very dangerous if high voltage is shorted to ground through the tools.)

  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0E2-773 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 Generator Control Module
      P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796 Drive Motor "A" Control Module
      P0A1D-148 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
      P0A94-442 DC / DC Converter Performance
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0AA4-232 Hybrid Battery Negative Contactor Circuit Stuck Closed
      P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P2511-149 ECM/PCM Power Relay Sense Circuit Intermittent
      P3004-132 Power Cable Malfunction
      P324E-788 MG-ECU Power Relay Intermittent Circuit
      U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0AE2-773 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

    5. Turn the power switch off.


    B
    A
  2. CHECK FREEZE FRAME DATA (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Read the freeze frame data of DTC P0AE2-773.

      Result
      Result Proceed to
      VL-Voltage before Boosting is less than 60 V. A
      VL-Voltage before Boosting is 60 V or more. B
    5. Turn the power switch off.


    A
    B
  3. CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the upper hybrid battery cover sub-assembly.

    3. A003XCSE04
      Text in Illustration
      *1 Hybrid Battery Junction Block Assembly

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      S3-1 (CEI) - h2-1 (-) Power switch off 10 kΩ or higher

      Tech Tips


      • If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.

      • If the result of reading the freeze frame data is B, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.

    4. Install the upper hybrid battery cover sub-assembly.


    NG
    OK