PURGE VALVE INSTALLATION


  1. INSTALL PURGE VSV


    1. Install the purge VSV with the bolt.

      Torque:
      21 N*m  { 214 kgf*cm, 15 ft.*lbf }
    2. Connect the 2 fuel vapor feed hoses and connector to the purge VSV.

  2. INSTALL AIR CLEANER CASE


    1. Install the air cleaner case with the 2 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
    2. Connect the water hose to the clamp.

    3. Install the air cleaner filter element sub-assembly to the air cleaner case.

  3. INSTALL INLET AIR CLEANER ASSEMBLY


    1. Install the inlet air cleaner assembly to the air cleaner case.

    2. Install the inlet air cleaner assembly with the 2 bolts and 2 clips.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
    3. Connect the wire harness clamp to the inlet air cleaner assembly.

    4. Install the water hose to the hose clamp.

  4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. Install the air cleaner cap sub-assembly with the 2 clamps.

    2. Connect the water hose to the clamp.

    3. Connect the air cleaner hose assembly and tighten the hose clamp.

    4. Connect the connector and wire harness clamp.

  5. INSTALL NO. 2 CYLINDER HEAD COVER


    1. A003WMM

      Engage the 3 clips to install the cover.

      Note


      • Be sure to engage the clips securely.

      • Do not apply excessive force or hit the cover to engage the clips. This may cause the cover to break.