| DTC Code | DTC Name |
|---|---|
| P0A1A-151 | Generator Control Module |
| P0A1A-155 | Generator Control Module |
| P0A1A-156 | Generator Control Module |
| P0A1A-166 | Generator Control Module |
| P0A1A-658 | Generator Control Module |
| P0A1A-659 | Generator Control Module |
| P0A1A-791 | Generator Control Module |
| P0A1B-163 | Drive Motor "A" Control Module |
| P0A1B-164 | Drive Motor "A" Control Module |
| P0A1B-192 | Drive Motor "A" Control Module |
| P0A1B-193 | Drive Motor "A" Control Module |
| P0A1B-198 | Drive Motor "A" Control Module |
| P0A1B-511 | Drive Motor "A" Control Module |
| P0A1B-512 | Drive Motor "A" Control Module |
| P0A1B-661 | Drive Motor "A" Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1B-794 | Drive Motor "A" Control Module |
DESCRIPTION
The MG ECU located in the inverter with converter assembly monitors its internal operation and it will set DTCs when it detects malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A1A | 151 | Run pulse signal cycle deviation or stop | Inverter with converter assembly |
| 155 | A/D converter error | ||
| 156 | CPU ROM-RAM error | ||
| 166 | R/D converter NM stop error | ||
| 658 | ALU error | ||
| 659 | Communication error (from MG1 to MG2) | ||
| 791 | R/D converter communication error | ||
| P0A1B | 163 | IPM positive power source error | |
| 164 | IPM negative power source error | ||
| 192 | A/D converter error | ||
| 193 | CPU ROM-RAM error | ||
| 198 | R/D converter NM stop error | ||
| 511 | Standard voltage for analog signal offset | ||
| 512 | Standard voltage for analog signal error | ||
| 661 | Communication error (from MG2 to MG1) | ||
| 786 | ALU error | ||
| 794 | R/D converter communication error |
INSPECTION PROCEDURE
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A-155, 156, 166, 658, 791 | Generator Control Module |
| P0A1B-163, 164, 192, 193, 198, 511, 512, 661, 786, 794 | Drive Motor "A" Control Module |
Turn the power switch off.
| B |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CLEAR DTC
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the intelligent tester to the DLC3.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY Click here |
| C |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY
Check the installation position of the part No. label on the inverter with converter assembly Click here.
Check the part number of the inverter with converter assembly.
| Result | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
| B |
|
REPLACE MG CONTROL COMPUTER Click here |
| A |
|
REPLACE MG CONTROL COMPUTER AND INVERTER CURRENT SENSOR AND INVERTER WIRE Click here
CHECK INVERTER WITH CONVERTER ASSEMBLY
Check the installation position of the part No. label on the inverter with converter assembly Click here.
Check the part number of the inverter with converter assembly.
| Result | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
| B |
|
REPLACE POWER MODULE INTELLIGENT TRANSISTOR KIT AND MG CONTROL COMPUTER Click here |
| A |
|
REPLACE POWER MODULE INTELLIGENT TRANSISTOR KIT AND MG CONTROL COMPUTER AND INVERTER CURRENT SENSOR AND INVERTER WIRE Click here