INTEGRATION RELAY INSPECTION


  1. INSPECT INTEGRATION NO.2 RELAY

    A003S3ME05
    Text in Illustration
    *1 Integration Relay - -

    1. IG2 RELAY:


      1. A003U0JE12
        Text in Illustration
        *1 Integration Relay

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Integration relay (1C-1) - Integration relay (1A-4) Battery voltage is not applied between terminals 1A-3 and 1A-2 10 kΩ or higher
        Integration relay (1C-1) - Integration relay (1A-4) Battery voltage is applied between terminals 1A-3 and 1A-2 Below 1 Ω

        If the resistance is not as specified, replace the integration relay.

    2. EFI MAIN RELAY:


      1. A003U0JE12
        Text in Illustration
        *1 Integration Relay

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Integration relay (1C-1) - Integration relay (1B-4) Battery voltage is not applied between terminals 1B-2 and 1B-3 10 kΩ or higher
        Integration relay (1C-1) - Integration relay (1B-4) Battery voltage is applied between terminals 1B-2 and 1B-3 Below 1 Ω

        If the resistance is not as specified, replace the integration relay.

    3. C/OPN RELAY:


      1. A003U0JE12
        Text in Illustration
        *1 Integration Relay

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Integration relay (1B-5) - Integration relay (1B-8) Battery voltage is not applied between terminals 1B-6 and 1B-7 10 kΩ or higher
        Integration relay (1B-5) - Integration relay (1B-8) Battery voltage is applied between terminals 1B-6 and 1B-7 Below 1 Ω

        If the resistance is not as specified, replace the integration relay.

    4. BATT FAN RELAY:


      1. A003U0JE12
        Text in Illustration
        *1 Integration Relay

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Integration relay (1C-1) - Integration relay (1A-8) Battery voltage is not applied between terminals 1A-7 and 1A-6 10 kΩ or higher
        Integration relay (1C-1) - Integration relay (1A-8) Battery voltage is applied between terminals 1A-7 and 1A-6 Below 1 Ω

        If the resistance is not as specified, replace the integration relay.