MASS AIR FLOW METER REMOVAL


  1. REMOVE NO. 2 CYLINDER HEAD COVER


    1. A003S7G

      Remove the 3 clips and No. 2 cylinder head cover.

      Note


      • Attempting to disengage both front and rear clips at the same time may cause the cover to break.

      • Pull the cover straight up to remove. Attempting to pull the cover forward may cause it to break.

  2. REMOVE MASS AIR FLOW METER


    1. A003SUO

      Disconnect the mass air flow meter connector.

    2. Remove the 2 screws and the mass air flow meter.