VACUUM SENSOR REMOVAL


  1. REMOVE NO. 2 CYLINDER HEAD COVER


    1. A003S7G

      Remove the 3 clips and No. 2 cylinder head cover.

      Note


      • Attempting to disengage both front and rear clips at the same time may cause the cover to break.

      • Pull the cover straight up to remove. Attempting to pull the cover forward may cause it to break.

  2. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A003RKT

      Disconnect the mass air flow meter connector.

    2. A003TOZE01

      Release the 2 clamps.

    3. Loosen the hose clamp and remove the air cleaner cap.

  3. REMOVE INLET AIR CLEANER ASSEMBLY


    1. A003TOE

      Separate the hose from the hose clamp.

    2. Separate the wire harness clamp from the inlet air cleaner assembly.

    3. Remove the 3 bolts and inlet air cleaner assembly.

  4. REMOVE AIR CLEANER CASE


    1. Remove the air cleaner filter element.

    2. A003SAW

      Separate the hose from the 3 hose clamps.

    3. Remove the 3 bolts and air cleaner case.

  5. REMOVE MANIFOLD ABSOLUTE PRESSURE SENSOR


    1. A003T4X

      Disconnect the connector.

    2. Remove the bolt and manifold absolute pressure sensor.