| DTC Code | DTC Name |
|---|---|
| P0A80-123 | Replace Hybrid Battery Pack |
DESCRIPTION
The HV battery uses nickel metal-hydride batteries and does not require external charging. The power management control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 28 modules, and each module consists of eight 1.2 V cells in series. The battery smart unit monitors battery block voltage at 14 locations. Each battery block is composed of 2 modules in a set.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0A80-123 | Difference in voltage between battery blocks is larger than the standard (2 trip detection) |
|
Tech Tips
P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC.
INSPECTION PROCEDURE
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK BATTERY SMART UNIT
Ensure the safety of the areas in front and at the back of the vehicle.
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Batt block Vol -V01 to V14.
Fully warm up the engine and turn the air conditioning off.
Firmly depress the brake pedal with your left foot.
Move the select lever to D.
Record each battery block voltage from the data list (Batt block Vol -V01 to V14) while fully depressing the accelerator pedal.
Compare the battery block voltages (VB0 to 13 Batt block) between the even and odd number groups in each combination shown in the table below.
| Even Number Group | Odd number group | Battery block voltages to be compared |
|---|---|---|
| V0 BATT BLOCK | V1 BATT BLOCK | VB0 - VB1 |
| V2 BATT BLOCK | V3 BATT BLOCK | VB2 - VB3 |
| V4 BATT BLOCK | V5 BATT BLOCK | VB4 - VB5 |
| V6 BATT BLOCK | V7 BATT BLOCK | VB6 - VB7 |
| V8 BATT BLOCK | V9 BATT BLOCK | VB8 - VB9 |
| V10 BATT BLOCK | V11 BATT BLOCK | VB10 - VB11 |
| V12 BATT BLOCK | V13 BATT BLOCK | VB12 - VB13 |
Check the difference in voltage of each combination.
| Result | Proceed to |
|---|---|
| Difference in voltage of each combination is 0.3 V or higher. | A |
| Other than above. | B |
Tech Tips
If the difference in voltage of each combination is 0.3 V or higher, it is due to a battery smart unit internal error.
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
| B |
|
REPLACE HV BATTERY Click here |
| A |
|
REPLACE BATTERY SMART UNIT Click here