HYBRID CONTROL SYSTEM Pattern Select Switch Eco Mode Circuit

DESCRIPTION

When selecting ECO mode, the switch operation signal is sent to the air conditioning amplifier assembly. Following this, ECO mode control is activated for the heater and air conditioning system.

WIRING DIAGRAM

A003RWCE09

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (CAN BUS CHECK)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: System Select / CAN Bus Check.

      Result
      Result Proceed to
      All of the ECUs and sensors that are currently connected to the CAN communication system are displayed. A
      None of the ECUs and sensors that are currently connected to the CAN communication system are displayed, or some of them are not displayed. B

    B
    A
  2. CHECK DTC OUTPUT (ALL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Check for DTCs of all system by following the prompts on the tester screen.

      Result
      Result Proceed to
      No DTCs are output A
      DTCs are output B

    B
    A
  3. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INDICAT. ECO MODE)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. ECO Mode.

    4. Perform the "Indicat. ECO MODE" Active Test.

      OK
      The ECO MODE indicator lamp comes on or blinks.
    5. Turn the power switch off.


    NG
    OK
  4. READ VALUE USING INTELLIGENT TESTER (ECO MODE)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Data List / ECO Mode.

    4. Read the value displayed on the intelligent tester.

      Tester Display Measurement Item/Range Normal Condition
      ECO Mode

      ECO mode transition availability/

      ON or OFF

      In EV mode: ON
      Result
      Result Proceed to
      The intelligent tester display changes according to the ECO switch operation. A
      The intelligent tester display does not changes according to the ECO switch operation. B

    B
    A
  5. READ VALUE USING INTELLIGENT TESTER (ECO SWITCH)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Body Electrical / Air Conditioning / Data List / ECO Switch.

    4. Read the value displayed on the intelligent tester.

      Tester Display Measurement Item/Range Normal Condition
      ECO Switch

      ECO mode switch condition/

      ON or OFF

      ECO mode switch operated: ON

      ECO mode switch not operated: OFF

      Result
      Result Proceed to
      The intelligent tester display changes according to the ECO switch operation. A
      The intelligent tester display does not changes according to the ECO switch operation. B

    B
    A
  6. CHECK COMBINATION SWITCH ASSEMBLY (ECO MODE)


    1. Remove the combination switch assembly.

    2. A003TF2E03
      Text in Illustration
      *a

      Component without harness connected

      (Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E115-2 (ECU) - E115-3 (E) ECO mode switch operated Below 1 Ω
      E115-2 (ECU) - E115-3 (E) ECO mode switch not operated 10 kΩ or higher
    3. Install the combination switch assembly.


    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - BODY GROUND)


    1. Disconnect connector E115 from the combination switch assembly.

    2. A003SDIE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E115-3 (E) - Body ground Always Below 1 Ω
    3. Connect the combination switch assembly connector.


    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COMBINATION SWITCH)


    1. Disconnect connector E30 from the air conditioning amplifier assembly.

    2. Disconnect connector E115 from the combination switch assembly.

    3. A003V0TE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      *b

      Front view of wire harness connector

      (to Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E30-15 (ECOS) - E115-2 (ECU) Always Below 1 Ω
      E30-15 (ECOS) or E115-2 (ECU) - Body ground Always 10 kΩ or higher
    4. Connect the combination switch assembly connector.

    5. Connect the air conditioning amplifier assembly connector.


    NG