HYBRID CONTROL SYSTEM Pattern Select Switch Power Mode Circuit

DESCRIPTION

When selecting power mode, the switch operation signal is sent to the ECM. Following this, the drive torque is optimally controlled to obtain a sporty feel in response to the driver's acceleration operation.

WIRING DIAGRAM

A003RWCE08

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (CAN BUS CHECK)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: System Select / CAN Bus Check.

      Result
      Result Proceed to
      All of the ECUs and sensors that are currently connected to the CAN communication system are displayed. A
      None of the ECUs and sensors that are currently connected to the CAN communication system are displayed, or some of them are not displayed. B

    B
    A
  2. CHECK DTC OUTPUT (ALL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Check for DTCs of all system by following the prompts on the tester screen.

      Result
      Result Proceed to
      No DTCs are output A
      DTCs are output B

    B
    A
  3. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INDICAT. LAMP ECT PWR)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. Lamp ECT PWR.

    4. Perform the "Indicat. Lamp ECT PWR" Active Test.

      OK
      The PWR mode indicator lamp comes on or blinks.
    5. Turn the power switch off.


    NG
    OK
  4. READ VALUE USING INTELLIGENT TESTER (PATTERN SWITCH (PWR/M))


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Data List / Pattern Switch (PWR/M).

    4. Read the value displayed on the intelligent tester.

      Tester Display Measurement Item/Range Normal Condition
      Pattern Switch (PWR/M)

      POWER mode transition availability/

      ON or OFF

      In POWER mode: ON
      Result
      Result Proceed to
      The intelligent tester display changes according to the POWER switch operation. A
      The intelligent tester display does not changes according to the POWER switch operation. B

    B
    A
  5. CHECK COMBINATION SWITCH ASSEMBLY (POWER MODE SWITCH)


    1. Remove the combination switch assembly.

    2. A003TF2E02
      Text in Illustration
      *a

      Component without harness connected

      (Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E115-8 (PWR) - E115-3 (E) PWR mode switch operated Below 1 Ω
      E115-8 (PWR) - E115-3 (E) PWR mode switch not operated 10 kΩ or higher
    3. Install the combination switch assembly.


    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - BODY GROUND)


    1. Disconnect connector E115 from the combination switch assembly.

    2. A003SDIE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E115-3 (E) - Body ground Always Below 1 Ω
    3. Connect the combination switch assembly connector.


    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (ECM - COMBINATION SWITCH ASSEMBLY)


    1. Disconnect connector A50 from the ECM.

    2. Disconnect connector E115 from the combination switch assembly.

    3. A003SMVE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      *b

      Front view of wire harness connector

      (to Combination Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A50-46 (PWMS) - E115-8 (PWR) Always Below 1 Ω
      A50-46 (PWMS) or E115-8 (PWR) - Body ground Always 10 kΩ or higher
    4. Connect the combination switch assembly connector.

    5. Connect the ECM connector.


    NG