WATER PUMP WITH MOTOR REMOVAL


  1. REMOVE ENGINE UNDER COVER

  2. REMOVE NO. 1 ENGINE UNDER COVER

  3. DRAIN COOLANT (for Inverter)

    Note


    • Do not reuse the drained coolant because it may contain foreign objects.

    • Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.


    1. Remove the reserve tank cap.

      CAUTION:

      To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.

    2. A003RRD

      Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.

      CAUTION:

      Use caution when handling coolant immediately after driving or in summer because it may be hot.

    3. Install the plug with a new gasket.

      Torque:
      39 N*m  { 397 kgf*cm, 29 ft.*lbf }
  4. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    Click here

  5. REMOVE INVERTER RESERVE TANK ASSEMBLY


    1. A003U7R

      Remove the 2 bolts and inverter reserve tank assembly.

  6. REMOVE INVERTER TRAY BRACKET


    1. A003TTD

      Separate the 2 clamps.

    2. Remove the 5 bolts and inverter tray bracket.

  7. REMOVE INVERTER WATER PUMP ASSEMBLY


    1. A003RHE

      Disconnect the 2 water hose and connector.

    2. A003UOR

      Remove the 3 bolts and the inverter water pump assembly with the water pump bracket.