HYBRID CONTROL SYSTEM, Diagnostic DTC:P0AA6-526, P0AA6-611, P0AA6-612, P0AA6-613, P0AA6-614

DTC Code DTC Name
P0AA6-526 Hybrid Battery Voltage System Isolation Fault
P0AA6-611 Hybrid Battery Voltage System Isolation Fault
P0AA6-612 Hybrid Battery Voltage System Isolation Fault
P0AA6-613 Hybrid Battery Voltage System Isolation Fault
P0AA6-614 Hybrid Battery Voltage System Isolation Fault

DESCRIPTION

The power management control ECU monitors the battery smart unit and detects insulation malfunctions in the high-voltage system.

DTC No. INF Code DTC Detection Condition Trouble Area
P0AA6 526(*1) Insulation resistance between the high-voltage circuit and the body has decreased.
  • Hybrid vehicle transaxle assembly

  • Motor cable

  • Generator cable

  • Inverter with converter assembly

  • Frame wire

  • No. 2 engine wire

  • Hybrid battery junction block

  • Compressor with motor assembly

  • HV battery

  • Battery smart unit

P0AA6 611 Insulation resistance of the compressor with motor assembly has decreased. Compressor with motor assembly
P0AA6 612 Insulation resistance of the HV battery area has decreased.
  • Hybrid battery junction block

  • Battery smart unit

  • HV battery

P0AA6 613 Insulation resistance of the transaxle area has decreased.
  • Hybrid vehicle transaxle assembly

  • Motor cable

  • Generator cable

  • Inverter with converter assembly

P0AA6 614 Insulation resistance of the high-voltage DC area has decreased.
  • Inverter with converter assembly

  • Frame wire

  • Compressor with motor assembly

  • No. 2 engine wire

  • Hybrid battery junction block

  • Hybrid vehicle transaxle assembly

  • Motor cable

  • Generator cable

Tech Tips


  • *1: INF code 526 is stored together with P0AA6.

  • If DTC P0AA6 is stored, the vehicle cannot start.

  • When measuring insulation resistance using a megohmmeter, measure the resistance while jiggling the high voltage wire harness.

WIRING DIAGRAM

A003UJGE01
Text in Illustration
*1 HV Battery *2 Service Plug Grip
*3 Battery Smart Unit *4 SMRB
*5 SMRG *6 SMRP
*7 System Main Resistor *8 Inverter with Converter Assembly
*9 Boost Converter *10 Inverter
*11 MG1 *12 MG2
*13 Compressor with Motor Assembly *14 A/C Inverter
*15 A/C Motor - -
*a High-voltage Areas *b INF Code 526 Vehicle Insulation Resistance Reduction Area
*c INF Code 611 Air Conditioning Area *d INF Code 612 HV Battery Area
*e INF Code 613 Transaxle Area *f INF Code 614 High Voltage Direct Current Area

SYSTEM DESCRIPTION

Tech Tips

If a decrease in insulation resistance cannot be confirmed using a megohmmeter, check the Short Wave Highest Val in the Data List.


  1. Characteristics of Short Wave Highest Value


    1. The Data List item Short Wave Highest Val and insulation resistance have the relationship shown in the table below. Short Wave Highest Val decreases with a decrease in insulation resistance. However, in some cases, even though the insulation resistance of the vehicle is normal, Short Wave Highest Val may decrease. Therefore, check Short Wave Highest Val while considering the following.


      • Do not check until approximately 1 minute has passed after the power switch is turned on (IG) (*1).

      • Do not check when there is a difference between the system voltages (HV battery voltage, VL-Voltage before boosting, and VH-Voltage after boosting) (*2).

        Short Wave Highest Value Trouble Area
        Neither condition (*1) nor (*2) is met and Short Wave Highest Val is approximately 0 V Since the insulation resistance is close to 0 Ω, there is a strong possibility of interference with a metal object.
        Neither condition (*1) nor (*2) is met and Short Wave Highest Val is between 0 and 5 V Since the insulation resistance is several hundred kiloohms, there is a strong possibility of the presence of fluid such as coolant.
  2. How to Determine Part with Insulation Malfunction


    1. Jiggle the high-voltage wire harness to check if the resistance to body ground changes with the position of the wire harness or force applied.

    2. Repeat rotating and stopping of the MG1, MG2 and compressor with motor. Check that the Short Wave Highest Val does not decrease (for example if the motor stops with foreign matter forming a leak path) when the motor stops, or that the Short Wave Highest Val does not return to normal (for example if foreign matter moves away from the leak path) when the motor rotates.

    3. Increase the temperature of MG1and MG2. Check if the Short Wave Highest Val decreases with the temperature increase.

INSPECTION PROCEDURE

CAUTION:


  • When troubleshooting P0AA6, be sure to wrap the tools with electrical tape. (It is very dangerous if high voltage is shorted to ground through the tools.)

  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

Tech Tips


  • Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

  • When measuring insulation resistance using a megohmmeter, set the megohmmeter to 500 V.

PROCEDURE


  1. CHECK DTC OUTPUT (HV)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0AA6 only is output. A
      P0AA6 and P0A1D (power management control ECU malfunction) are output. B
      P0AA6 and P0AA7 (malfunction in the battery smart unit) are output. C
      P0AA6 and P0AFC (battery ECU malfunction) are output. D
    5. Turn the power switch off.


    B
    C
    D
    A
  2. CHECK INFORMATION CODE


    1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    2. Access the freeze frame data of DTC P0AA6 and read the INF code.

      Note

      INF codes 611, 612, 613 and 614 are not stored at the same time with INF code 526. If INF code 526 only is output, turn the power switch off and wait 30 seconds to determine the malfunctioning area. Then, turn the power switch on (IG) and read the INF code again.

      Result
      Result Proceed to
      526 (decrease in the insulation resistance of the high-voltage circuit) only is output A
      526 and 611 (decrease in the insulation resistance of the air conditioning area) are output

      Refer to the troubleshooting procedures for P0AA6-611 (Heater and air conditioning system) Click here

      526 and 612 (decrease in the insulation resistance of the battery area) are output B
      526 and 613 (decrease in the insulation resistance of the transaxle area) are output C
      526 and 614 (decrease in the insulation resistance of the high-voltage DC area) are output D

    B
    C
    D
    A
  3. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. A003UIY

      Remove the inverter terminal cover from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.

    4. A003SHPE02
      Text in Illustration
      *1 Motor Cable
      *2 Generator Cable

      Disconnect the motor cable X1 and generator cable Y1 from the inverter with converter assembly.

    5. A003S65E06
      Text in Illustration
      *1 Motor Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      X1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  4. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003UOGE05
      Text in Illustration
      *1 Generator Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Y1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  5. CHECK NO. 2 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003UY8E02

      Disconnect the No. 2 engine wire (air conditioning harness) G2 from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the connector of the No. 2 engine wire (air conditioning harness) G2.

    3. A003SQJE03
      Text in Illustration
      *1

      No. 2 Engine Wire

      (Air Conditioning Harness)

      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      G2-1 (ACPB) - Body ground and shielded wire ground Power switch off 3 MΩ or higher
      G2-2 (ACPE) - Body ground and shielded wire ground Power switch off 3 MΩ or higher

    NG
    OK
  6. CHECK INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003RMOE02

      Disconnect the frame wire P1 from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the connector of the frame wire P1.

    3. A003SWW

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      High voltage terminal - Body ground Power switch off 1 MΩ or higher

      Tech Tips

      Perform this inspection with the motor cable, generator cable and No. 2 engine wire (air conditioning harness) disconnected from the inverter with converter assembly.


    NG
    OK
  7. CHECK FRAME WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003S1CE03
      Text in Illustration
      *1 Frame Wire

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      P1-1 (CEI) - Body ground Power switch off 10 MΩ or higher
      P1-2 (CBI) - Body ground Power switch off 10 MΩ or higher

    NG
    OK
  8. CHECK HV BATTERY AREA

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. A003TJPE02

      Disconnect connector b1 from the battery smart unit.

      Tech Tips

      For the removal and installation procedures related to the battery smart unit connectors, Click here.

    4. A003S6WE01

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - Body ground Power switch off 10 MΩ or higher
      2 - Body ground Power switch off 10 MΩ or higher

    NG
    OK
  9. CHECK INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. A003UIY

      Remove the inverter terminal cover from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.

    4. A003SHPE02
      Text in Illustration
      *1 Motor Cable
      *2 Generator Cable

      Disconnect the motor cable X1 and generator cable Y1 from the inverter with converter assembly.

    5. A003RSH

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      High voltage terminal - Body ground Power switch off 1 MΩ or higher
      Result
      Result Proceed to
      NG A
      OK B

    B
    A
  10. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. A003UIY

      Remove the inverter terminal cover from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.

    4. A003SHPE02
      Text in Illustration
      *1 Motor Cable
      *2 Generator Cable

      Disconnect the motor cable X1 and generator cable Y1 from the inverter with converter assembly.

    5. A003S65E06
      Text in Illustration
      *1 Motor Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      X1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  11. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003UOGE05
      Text in Illustration
      *1 Generator Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Y1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  12. CHECK HIGH VOLTAGE DIRECT CURRENT AREA

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. A003THYE02

      Disconnect the frame wire P1 from the inverter with converter assembly.

      Tech Tips

      Make sure that no foreign objects have entered or contaminated the connector of the frame wire P1.

    4. A003S1CE03
      Text in Illustration
      *1 Frame Wire

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      P1-1 (CEI) - Body ground Power switch off 10 MΩ or higher
      P1-2 (CBI) - Body ground Power switch off 10 MΩ or higher

    NG
    OK
  13. CHECK NO. 2 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003RWHE02

      Disconnect the No. 2 engine wire (air conditioning harness) G2 from the inverter with converter assembly.

    3. A003SQJE03
      Text in Illustration
      *1

      No. 2 Engine Wire

      (Air Conditioning Harness)

      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      G2-1 (ACPB) - Body ground and shielded wire ground Power switch off 3 MΩ or higher
      G2-2 (ACPE) - Body ground and shielded wire ground Power switch off 3 MΩ or higher

    NG
    OK
  14. CHECK NO. 2 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003SF5E02
      Text in Illustration
      *1 Green Lock

      Disconnect the No. 2 engine wire (air conditioning harness) G1 from the compressor with motor assembly.

    3. A003SQJE03
      Text in Illustration
      *1

      No. 2 Engine Wire

      (Air Conditioning Harness)

      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      G2-1 (ACPB) - Body ground and shielded wire ground Power switch off 10 MΩ or higher
      G2-2 (ACPE) - Body ground and shielded wire ground Power switch off 10 MΩ or higher

    NG
    OK
  15. CHECK FRAME WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003RIQE04

      Disconnect the frame wire P4 and P3 from the hybrid battery junction block.

      Tech Tips

      For the removal and installation procedures related to the frame wire, Click here.

    3. A003RNEE02

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      P4-1 (CBI) - Body ground and shielded wire ground Power switch off 10 MΩ or higher
      P3-1 (CEI) - Body ground and shielded wire ground Power switch off 10 MΩ or higher

    NG
    OK
  16. CHECK HYBRID BATTERY JUNCTION BLOCK

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A003UKPE02

      Disconnect the high voltage cable connector of the HV battery a2 and c2 from the hybrid battery junction block.

    3. A003UV1E02

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      c2-1 (-) - Hybrid Battery Carrier Panel Power switch off 10 MΩ or higher
      a2-1 (+) - Hybrid Battery Carrier Panel Power switch off 10 MΩ or higher

    NG
    OK
  17. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. Disconnect the motor cable from the hybrid vehicle transaxle assembly Click here.

    4. A003S65E06
      Text in Illustration
      *1 Motor Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      X1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  18. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the generator cable from the hybrid vehicle transaxle assembly Click here.

    3. A003UOGE05
      Text in Illustration
      *1 Generator Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Y1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  19. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Turn the power switch off.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. Disconnect the motor cable from the hybrid vehicle transaxle assembly Click here.

    4. A003S65E06
      Text in Illustration
      *1 Motor Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      X1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      X1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG
    OK
  20. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the generator cable from the hybrid vehicle transaxle assembly Click here.

    3. A003UOGE05
      Text in Illustration
      *1 Generator Cable
      *2 Shielded Wire Ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Y1-3 (V) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-2 (U) - Body ground and shielded wire ground Power switch off 100 MΩ or higher
      Y1-1 (W) - Body ground and shielded wire ground Power switch off 100 MΩ or higher

    NG