DESCRIPTION
The illuminated entry system controls the interior lights.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Active Test.
Check that the lights operate.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Illuminated Entry System | No. 1 room light assembly | ON/OFF | No. 1 room light assembly switch in DOOR position and all doors closed |
| OK |
|---|
| Each light fades in. |
| NG |
|
CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the 2A instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
| *1 | Component without harness connected (Instrument Panel Junction Block Assembly) |
Remove the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)