ENTRY AND START SYSTEM (for Start Function) Power Source Mode does not Change to ON (IG)

DESCRIPTION

When the power switch is pushed with the electrical key in the cabin, the power management control ECU receives signals to change the power source mode.

Tech Tips

To allow use of the intelligent tester to inspect the push-button start function when the power source mode is off, repeat opening and closing any of the doors. Opening and closing a door establishes communication between the intelligent tester and power management control ECU. (Opening and closing a door can also be simulated by operating a door courtesy light switch.)

WIRING DIAGRAM

Refer to DTC B2271 Click here.

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)


    1. Disconnect the E111 and E112 connectors from the power management control ECU.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      E111-1 (AM22) - Body ground Always 9.5 to 16 V
      E112-7 (AM21) - Body ground Always 9.5 to 16 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E111-5 (E01) - Body ground Always Below 1 Ω
      E111-6 (E1) - Body ground Always Below 1 Ω
      E112-4 (E12) - Body ground Always Below 1 Ω
      E112-5 (E02) - Body ground Always Below 1 Ω

    NG
    OK
  3. INSPECT NO.2 INTEGRATION RELAY


    1. A003T8YE01
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2B-25 - 2B-4 20°C (68°F) 101.25 to 123.75 Ω
      2B-25 - 2B-6 20°C (68°F) 101.25 to 123.75 Ω
      2B-4 - 2B-6 Always Below 1 Ω

    NG
    OK
  4. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 1, IG1 NO. 2 AND IG1 NO. 3 RELAY)


    1. A003T8YE01
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2B-25 - 2B-4 20°C (68°F) 101.25 to 123.75 Ω
      2B-25 - 2B-6 20°C (68°F) 101.25 to 123.75 Ω
      2B-4 - 2B-6 Always Below 1 Ω

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL J/B)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E112-2 (IG1D) - 2B-25 Always Below 1 Ω
      E112-2 (IG1D) - Body ground Always 10 kΩ or higher

    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2B-4 - Body ground Always Below 1 Ω
      2B-6 - Body ground Always Below 1 Ω

    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A99-2 (IG2D) - 1A-2 Always Below 1 Ω
      A99-2 (IG2D) - Body ground Always 10 kΩ or higher

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (NO.2 INTEGRATION RELAY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1A-3 - Body ground Always Below 1 Ω

    NG
    OK
  9. CHECK POWER MANAGEMENT CONTROL ECU


    1. A003S4GE06
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Install the instrument panel junction block assembly.

    2. Install the No.2 integration relay.

    3. Reconnect the A99 and E112 connectors.

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A99-2 (IG2D) - Body ground Power switch on (IG) Output voltage at terminal AM21 or AM22 is -2.5 V or more
      E112-2 (IG1D) - Body ground Power switch on (IG) Output voltage at terminal AM21 or AM22 is -2.5 V or more

    NG