AIR CONDITIONING SYSTEM Back-up Power Source Circuit

DESCRIPTION

The back-up power source circuit for the A/C amplifier is shown below. Power is supplied even when the power switch is turned off. The power is used for diagnostic trouble code memory etc.

WIRING DIAGRAM

A01JB48E04

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - BATTERY)


    1. A01JAUIE71
      Text in Illustration
      *1

      Front view of wire harness connector

      (to A/C Amplifier)

      Disconnect the A/C amplifier connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L17-21 (B) - Body ground Power switch off 11 to 14 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - BODY GROUND)


    1. A01JAUIE72
      Text in Illustration
      *1

      Front view of wire harness connector

      (to A/C Amplifier)

      Disconnect the A/C amplifier connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L17-14 (GND) - Body ground Always Below 1 Ω

    NG
    OK