SOLAR VENTILATION SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Solar Ventilation Switch

      Solar ventilation switch (Switch recognition value at A/C amplifier side) /

      OFF or ON

      OFF: Solar ventilation switch off

      ON: Solar ventilation switch on

      -
      Solar Voltage

      Solar panel voltage /

      10V les, 10V-11V, 11V-12V, 12V-13V, 13V-14V, 14V-15V, 15V-16V, 16V-17V, 17V-18V, 18V-19V, 19V-20V, 20V-21V, 21V-22V, 22V-23V or 23V ovr

      Actual generated voltage displayed

      System operation requirements are met Click here.

      Solar Ventilation Switch Status

      Solar ventilation switch (Switch recognition value at solar ventilation ECU side) /

      OFF or ON

      OFF: Solar ventilation switch off

      ON: Solar ventilation switch on

      -
      Solar IG Status

      Solar ventilation ECU IG status /

      OFF or ON

      OFF: Power switch off

      ON: Power switch on (IG)

      When OFF is displayed, a malfunction in the solar ventilation ECU is suspected.
      Solar Ventilation Test Mode Status

      Solar ventilation ECU test mode status /

      OFF or ON

      OFF: Test mode off

      ON: Test mode on

      -

      Tech Tips

      If the Data List items related to the solar ventilation system are not displayed, the following conditions are suspected:


      • The voltage generated by the moon roof glass assembly (solar panel) is less than 7 V Click here.

      • There is a communication error between the solar ventilation ECU and A/C amplifier Click here.

  2. ACTIVE TEST

    Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor Min.: 0, Max.: 31 -