AIR CONDITIONING SYSTEM CUSTOMIZE PARAMETERS

Tech Tips

The following items can be customized.

Note


  • When the customer requests a change in a function, first make sure that the function can be customized.

  • Be sure to make a note of the current settings before customizing.

  • When troubleshooting a function, first make sure that the function is set to the default setting.

Air Conditioner
Display (Item) Default Content Setting
Set Temperature Shift Normal Function to control with the shifted temperature against the displayed temperature. +2 C, +1 C, Normal, -1 C or -2 C
Air Inlet Mode Automatic Function to shift from INLET mode to RECIRCULATION mode when the A/C is turned on. Manual or Automatic
Foot/DEF Auto Mode ON Function to automatically turn the airflow from FOOT/DEF on when AUTO mode is on. OFF or ON
Foot/DEF Automatic Blow Up Function ON Function to automatically increase the blower level when the defroster is on. OFF or ON
Ambient Temperature Shift Normal Function to control the shifted ambient temperature in relation to the displayed ambient temperature. +3 C, +2 C, +1 C, Normal, -1 C, -2 C or -3 C
ECO MODE Cancel OFF Function to cancel the ECO mode drive when item is on. OFF or ON
Noise and Vibration Reduction OFF Function to change speed of the compressor when item is on. OFF or ON
Start Pre A/C*1 Long1 Function to set the activation operation method for the remote air conditioning system using the key (electrical transmitter). 1 tim ON, 2 tim ON, Long1 or Long2
Stop Pre A/C*1 2 tim ON Function to set the stop operation method for the remote air conditioning system using the key (electrical transmitter). 1 tim ON, 2 tim ON, Long1 or Long2