LIGHTING SYSTEM Interior Light Circuit

DESCRIPTION

The illuminated entry system controls the interior lights.

WIRING DIAGRAM

A01J9F6E01

INSPECTION PROCEDURE

PROCEDURE


  1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Main Body / Active Test.

    5. Check that the lights operate.

      Main Body
      Tester Display Test Part Control Range Diagnostic Note
      Illuminated Entry System Interior lights ON/OFF Interior light door switch on and all doors closed
      OK
      Each light fades in.

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. A01JCV5E01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Disconnect the 2A instrument panel junction block assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      2A-52 - Body ground Always 11 to 14 V

    NG
    OK
  3. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. A01JCJQE01
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-52 - A-1 (ILE) Always Below 1 Ω
      A-1 (ILE) - Body ground Always 10 kΩ or higher

    NG
    OK