ENTRY AND START SYSTEM (for Start Function), Diagnostic DTC:B2274

DTC Code DTC Name
B2274 ACC Monitor Malfunction

DESCRIPTION

This DTC is stored when there is a problem in the ACC output circuit. The ACC circuit is the circuit that goes from inside the power management control ECU to the ACC relay.

DTC No. DTC Detection Condition Trouble Area
B2274 The ACC relay actuation circuit inside the power management control ECU or other related circuit is malfunctioning.
  • AM2 fuse

  • ACC relay

  • Power management control ECU

  • Instrument panel junction block assembly

  • Wire harness or connector

WIRING DIAGRAM

A01JABUE01

INSPECTION PROCEDURE

Note


  • When the power management control ECU is replaced with a new one and the cable from the negative (-) auxiliary battery terminal is connected, the power source mode becomes on (IG) mode. When the auxiliary battery is removed and reinstalled, the power source mode that was selected when the auxiliary battery was removed is restored.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)


    1. Disconnect the L5 and L6 connectors from the power management control ECU.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L5-1 (AM22) - Body ground Always 9.5 to 16 V
      L6-7 (AM21) - Body ground Always 9.5 to 16 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L5-5 (E01) - Body ground Always Below 1 Ω
      L5-6 (E1) - Body ground Always Below 1 Ω
      L6-4 (E12) - Body ground Always Below 1 Ω
      L6-5 (E02) - Body ground Always Below 1 Ω

    NG
    OK
  3. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. A01J9T5E03
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-43 - 2B-4 20°C (68°F) 81.49 to 118.98 Ω
      2A-43 - 2B-6 20°C (68°F) 81.49 to 118.98 Ω
      2B-4 - 2B-6 Always Below 1 Ω

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL J/B)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L6-1 (ACCD) - 2A-43 Always Below 1 Ω
      L6-1 (ACCD) - Body ground Always 10 kΩ or higher

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2B-4 - Body ground Always Below 1 Ω
      2B-6 - Body ground Always Below 1 Ω

    NG
    OK
  6. INSPECT POWER MANAGEMENT CONTROL ECU


    1. A01J9LVE04
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Reinstall the instrument panel junction block assembly.

    2. Reconnect the L5 and L6 connectors.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L6-1 (ACCD) - Body ground Power switch on (ACC) Output voltage at terminal AM21 or AM22 is -2.5 V or more

    NG
    OK