CHECK FREEZE FRAME DATA
Tech Tips
The transmission control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. Freeze frame data can help determine the vehicle conditions when the malfunction occurred and help duplicate conditions when troubleshooting.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Transmission Control / Trouble Codes.
Select a DTC in order to display its freeze frame data.
LIST OF FREEZE FRAME DATA
| Tester Display | Measurement Item | Reference Value |
|---|---|---|
| Shift Pos Display (P) | Shift position display (P) | ON / OFF |
| Shift Pos Display (Not P) | Shift position display (not P) | ON / OFF |
| Master Caution Display | Master caution display | Disp / Nondisp |
| PSW Indicator Mode | PSW indicator mode | OFF / ON / Blink |
| U Phase Voltage Value | U phase voltage value | 0 to 39 V |
| V Phase Voltage Value | V phase voltage value | 0 to 39 V |
| W Phase Voltage Value | W phase voltage value | 0 to 39 V |
| Battery Voltage Value | BATT voltage value | 0 to 19 V |
| IG(+B) Voltage Value | IG (+B) voltage value | 0 to 19 V |
| Cmplte of Learn Lck Pos | Completion of learning lock position | OK / NG |
| Cmplte of Learn Unlck Pos | Completion of learning unlock position | OK / NG |
| # of Trip Cuntr after Learn | Number of trip counter after learning | 0 to 65535 |
| Main Relay for Motor Drive | Integration relay for motor drive | ON / OFF |
| U Phase Crnt-Carry Status | U phase current-carrying status | ON / OFF |
| V Phase Crnt-Carry Status | V phase current-carrying status | ON / OFF |
| W Phase Crnt-Carry Status | W phase current-carrying status | ON / OFF |
| U Phase Voltage Status | U phase voltage status | ON / OFF |
| V Phase Voltage Status | V phase voltage status | ON / OFF |
| W Phase Voltage Status | W phase voltage status | ON / OFF |
| Battery Voltage Status | BATT voltage status | ON / OFF |
| IG(+B) Phase Vol Status | IG (+B) phase voltage status | ON / OFF |
| ACC Condition Signal | ACC condition signal | ON / OFF |
| Init Drv Cntrl Completed | Initial drive control completed | OK / NG |
| Cmplte of Detct Lck Pos | Completion of detecting lock position | OK / NG |
| Cmplte of Detct Unlck Pos | Completion of detecting unlock position | OK / NG |
| P/Not P Move Shft Range | P/Not P movable shift range | Set / Unset |
| Main Relay | Integration relay | Normal / Abnoml |
| Current flag record | Current flag record | ON / OFF |
| Fail Rank | Fail rank | 0 to 255 |
| Detail Information # | - | - |