DYNAMIC RADAR CRUISE CONTROL SYSTEM Millimeter Wave Radar Sensor Power Source Circuit

DESCRIPTION

When the power switch is turned on (IG), battery voltage is applied to terminal IGB of the millimeter wave radar sensor assembly.

This circuit provides power to the millimeter wave radar sensor. The millimeter wave radar sensor emits radio waves towards an object in front and measures the distance and direction of the object by receiving the beam reflections. Based on the reflections, the sensor calculates the difference in speed between the vehicle and the object in front. This data is transmitted to the distance control ECU.

WIRING DIAGRAM

A01J8SRE02

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK MILLIMETER WAVE RADAR SENSOR ASSEMBLY (IGB VOLTAGE)

    A01JAQRE15
    Text in Illustration
    *1

    Front view of wire harness connector

    (to Millimeter Wave Radar Sensor Assembly)


    1. Disconnect the millimeter wave radar sensor assembly connector.

    2. Turn the power switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A2-5 (IGB) - A2-2 (SGND) Power switch on (IG) 10 to 14 V
    4. Reconnect the millimeter wave radar sensor assembly connector.


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BODY GROUND)


    1. A01JAQRE16
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Millimeter Wave Radar Sensor Assembly)

      Disconnect the millimeter wave radar sensor assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      A2-2 (SGND) - Body ground Always Below 1 Ω
    3. Reconnect the millimeter wave radar sensor assembly connector.


    NG
    OK