PURGE VALVE INSPECTION


  1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY


    1. A01J98W

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω

      If the result is not as specified, replace the vacuum switching valve assembly.

    2. Check operation of the vacuum switching valve assembly.


      1. A01J8RBE01
        Text in Illustration
        *1 Port F
        *2 Port E
        *3 Air Blow

        Blow air into port E. Check that air does not come out of port F.

      2. A01JCK2E01
        Text in Illustration
        *1 Port F
        *2 Port E
        *3 Air Blow

        Apply battery voltage across the terminals.

      3. Blow air into port E. Check that air comes out from port F.

        If the result is not as specified, replace the vacuum switching valve assembly.