INSPECT VACUUM SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the vacuum switching valve assembly.
Check operation of the vacuum switching valve assembly.
| *1 | Port F |
| *2 | Port E |
| *3 | Air Blow |
Blow air into port E. Check that air does not come out of port F.
| *1 | Port F |
| *2 | Port E |
| *3 | Air Blow |
Apply battery voltage across the terminals.
Blow air into port E. Check that air comes out from port F.
If the result is not as specified, replace the vacuum switching valve assembly.