DESCRIPTION
The HV battery uses nickel metal-hydride batteries and does not require external charging. The power management control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 28 modules, and each module consists of eight 1.2 V cells in series. The battery smart unit monitors battery block voltage at 14 locations. Each battery block is composed of 2 modules in a set.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0A80-123 | Difference in voltage between battery blocks is larger than the standard (2 trip detection) |
|
Tech Tips
P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)
DTC P0A80-123 is stored when a malfunction is detected in the HV battery or battery smart unit. If the HV supply battery is malfunctioning, the malfunction may not be reproduced when the condition of the HV supply battery changes due to difference in driving load (amperage), battery SOC and battery temperature. Therefore, use the freeze frame data when performing a repair.
When the HV battery is malfunctioning:
- Voltage of 1 or a few battery blocks has dropped. (voltage difference from that of the next block is 1 V or more.)
- Voltage of all battery blocks is output randomly with no certain pattern.
When the battery smart unit is malfunctioning:
- Differences in battery block voltages have a certain pattern.
INSPECTION PROCEDURE
PROCEDURE
CHECK DTC OUTPUT (DTC P0AFC-123 IS OUTPUT)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Disconnect the intelligent tester from the DLC3.
| B |
|
GO TO DTC CHART |
| A |
|
CHECK FREEZE FRAME DATA
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
Using the intelligent tester, make a note of the freeze frame data item "Battery Block Vol -V01 to V14".
Compare the freeze frame data item "Battery Block Vol -V01 to V14" values with those shown in the following combination tables.
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol-V01 (VB1) | Battery Block Vol-V02 (VB2) | "Battery Block Vol - V01" - "Battery Block Vol - V02" = 0.3 V or more |
| Battery Block Vol-V04 (VB4) | Battery Block Vol-V03 (VB3) | "Battery Block Vol - V04" - "Battery Block Vol - V03" = 0.3 V or more |
| Battery Block Vol-V05 (VB5) | Battery Block Vol-V06 (VB6) | "Battery Block Vol - V05" - "Battery Block Vol - V06" = 0.3 V or more |
| Battery Block Vol-V08 (VB8) | Battery Block Vol-V07 (VB7) | "Battery Block Vol - V08" - "Battery Block Vol - V07" = 0.3 V or more |
| Battery Block Vol-V09 (VB9) | Battery Block Vol-V10 (VB10) | "Battery Block Vol - V09" - "Battery Block Vol - V10" = 0.3 V or more |
| Battery Block Vol-V12 (VB12) | Battery Block Vol-V11 (VB11) | "Battery Block Vol - V12" - "Battery Block Vol - V11" = 0.3 V or more |
| Battery Block Vol-V13 (VB13) | Battery Block Vol-V14 (VB14) | "Battery Block Vol - V13" - "Battery Block Vol - V14" = 0.3 V or more |
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol-V01 (VB1) | Battery Block Vol-V02 (VB2) | "Battery Block Vol - V02" - "Battery Block Vol - V01" = 0.3 V or more |
| Battery Block Vol-V04 (VB4) | Battery Block Vol-V03 (VB3) | "Battery Block Vol - V03" - "Battery Block Vol - V04" = 0.3 V or more |
| Battery Block Vol-V05 (VB5) | Battery Block Vol-V06 (VB6) | "Battery Block Vol - V06" - "Battery Block Vol - V05" = 0.3 V or more |
| Battery Block Vol-V08 (VB8) | Battery Block Vol-V07 (VB7) | "Battery Block Vol - V07" - "Battery Block Vol - V08" = 0.3 V or more |
| Battery Block Vol-V09 (VB9) | Battery Block Vol-V10 (VB10) | "Battery Block Vol - V10" - "Battery Block Vol - V09" = 0.3 V or more |
| Battery Block Vol-V12 (VB12) | Battery Block Vol-V11 (VB11) | "Battery Block Vol - V11" - "Battery Block Vol - V12" = 0.3 V or more |
| Battery Block Vol-V13 (VB13) | Battery Block Vol-V14 (VB14) | "Battery Block Vol - V14" - "Battery Block Vol - V13" = 0.3 V or more |
Tech Tips
When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 7 pairs of blocks) will occur.
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
| B |
|
REPLACE HV BATTERY ASSEMBLY Click here |
| A |
|
REPLACE BATTERY SMART UNIT Click here