HYBRID CONTROL SYSTEM, Diagnostic DTC:U0110-160

DTC Code DTC Name
U0110-160 Lost Communication with Driver Motor Control Module

DESCRIPTION

Refer to the description for DTC U0110-159 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
U0110 160 Error in signal transmission to the inverter with converter assembly (MG ECU) via serial communication (no transmission, out of communication standard)
  • Wire harness or connector

  • Inverter with converter assembly

  • Hybrid vehicle transaxle assembly

  • Generator cable

  • Motor cable

  • Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC U0110-159 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

If the DTC U0110-160 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is on (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check the DTCs are not output.


  1. Turn the power switch on (IG) and wait for 2 minutes or more.

PROCEDURE


  1. CLEAR DTC


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Clear DTCs and freeze frame data.


    NEXT
  2. CHECK DTC OUTPUT (HV)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      DTC U0110-160 is output. A
      DTC U0110-160 is not output. B
    5. Turn the power switch off.


    B
    A
  3. CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01J95T

      Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01J99YE02

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      Bolt A
      8.0 N*m (82 kgf*cm, 71 in.*lbf)
      Bolt B
      9.2 N*m (94 kgf*cm, 81 ft.*lbf)

      Note

      Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the generator cable from the inverter with converter assembly.

    5. Check for arc marks at the bolts for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the inverter with converter assembly.

    7. Install the inverter terminal cover.


    B
    C
    A
  4. CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01J95T

      Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01JAW1E02

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      Bolt A
      8.0 N*m (82 kgf*cm, 71 in.*lbf)
      Bolt B
      9.2 N*m (94 kgf*cm, 81 ft.*lbf)

      Note

      Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the motor cable from the inverter with converter assembly.

    5. Check for arc marks at the bolts for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the motor cable to the inverter with converter assembly.

    7. Install the inverter terminal cover.


    B
    C
    A
  5. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01J95T

      Remove the inverter terminal cover from the inverter with converter assembly.

    3. Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A01JD0JE02
      Text in Illustration
      *1 Generator Cable
      *2 Shield Ground

      Check MG1 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        f1-1 (W) - f1-2 (U) Power switch off 89.5 to 98.9mΩ
        f1-2 (U) - f1-3 (V) Power switch off 89.5 to 98.9mΩ
        f1-3 (V) - f1-1 (W) Power switch off 89.5 to 98.9mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (° C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the inverter terminal cover.


    NG
    OK
  6. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01J95T

      Remove the inverter terminal cover from the inverter with converter assembly.

    3. Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A01JC44E01
      Text in Illustration
      *1 Motor Cable
      *2 Shield Ground

      Check MG2 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        e1-1 (W) - e1-2 (U) Power switch off 152.6 to 169.0 mΩ
        e1-2 (U) - e1-3 (V) Power switch off 157.6 to 174.0 mΩ
        e1-3 (V) - e1-1 (W) Power switch off 151.6 to 168.0 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (° C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the inverter terminal cover.


    NG
    OK
  7. CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)


    1. Turn the power switch on (IG).

    2. A01JBAJE04
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Connect an oscilloscope between the power management control ECU terminals specified in the following table, and measure the waveform.

      Item Contents
      Tester Connection

      CH1: A22-24 (HTM+) - L5-6 (E1)

      CH2: A22-25 (HTM-) - L5-6 (E1)

      Equipment Setting 1V/DIV., 200μs/DIV.
      Condition Power switch on (IG)
      Result
      Result Proceed to
      The waveform appears as shown in the illustration. A
      The waveform differs from the one shown in the illustration. B

      Tech Tips


      • Inspect with the connector connected.

      • If pulses are generated, the shape of the waveform can be assumed to be normal.

      • The shape of the waveform may vary according to communication conditions.

    3. Turn the power switch off.


    B
    A
  8. CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)


    1. Turn the power switch on (IG).

    2. A01J9UTE03
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Connect an oscilloscope between the power management control ECU terminals specified in the following table, and measure the waveform.

      Item Contents
      Tester Connection

      CH1: A22-21 (CLK+) - L5-6 (E1)

      CH2: A22-20 (CLK-) - L5-6 (E1)

      Equipment Setting 1V/DIV., 1μs/DIV.
      Condition Power switch on (IG)
      Result
      Result Proceed to
      The waveform appears as shown in the illustration. A
      The waveform differs from the one shown in the illustration. B

      Tech Tips


      • Inspect with the connector connected.

      • If pulses are generated, the shape of the waveform can be assumed to be normal.

      • The shape of the waveform may vary according to communication conditions.

    3. Turn the power switch off.


    B
    A
  9. CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)


    1. Turn the power switch on (IG).

    2. A01JA9HE02
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Connect an oscilloscope between the power management control ECU terminals specified in the following table, and measure the waveform.

      Item Contents
      Tester Connection

      CH1: A22-33 (REQ+) - L5-6 (E1)

      CH2: A22-32 (REQ-) - L5-6 (E1)

      Equipment Setting 1V/DIV., 1ms/DIV.
      Condition Power switch on (IG)
      Result
      Result Proceed to
      The waveform appears as shown in the illustration. A
      The waveform differs from the one shown in the illustration. B

      Tech Tips


      • Inspect with the connector connected.

      • If pulses are generated, the shape of the waveform can be assumed to be normal.

      • The shape of the waveform may vary according to communication conditions.

    3. Turn the power switch off.


    B
    A
  10. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A22 from the power management control ECU.

    3. Disconnect connector A59 from the inverter with converter assembly.

    4. Turn the power switch on (IG).

    5. A01JBUZE01
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A22-21 (CLK+) - Body ground Power switch on (IG) Below 1 V
      A22-20 (CLK-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the connector of the power management control ECU and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A22-21 (CLK+) - A59-5 (CLK+) Power switch off Below 1 Ω
      A22-20 (CLK-) - A59-15 (CLK-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A22-21 (CLK+) or A59-5 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A22-20 (CLK-) or A59-15 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher
    8. Connect the inverter with converter assembly connector.

    9. Connect the power management control ECU connector.


    NG
    OK
  11. CHECK INVERTER WITH CONVERTER ASSEMBLY


    1. Disconnect connector A22 from the power management control ECU.

    2. A01JC31E06
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A22-21 (CLK+) - A22-20 (CLK-) Power switch off 80 to 170 Ω
    3. Connect the power management control ECU connector.


    NG
    OK
  12. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A22 from the power management control ECU.

    3. Disconnect connector A59 from the inverter with converter assembly.

    4. Turn the power switch on (IG).

    5. A01JBUZE04
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A22-33 (REQ+) - Body ground Power switch on (IG) Below 1 V
      A22-32 (REQ-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the connector of the power management control ECU and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A22-33 (REQ+) - A59-6 (REQ+) Power switch off Below 1 Ω
      A22-32 (REQ-) - A59-16 (REQ-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A22-33 (REQ+) or A59-6 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A22-32 (REQ-) or A59-16 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
    8. Connect the inverter with converter assembly connector.

    9. Connect the power management control ECU connector.


    NG
    OK
  13. CHECK INVERTER WITH CONVERTER ASSEMBLY


    1. Disconnect connector A22 from the power management control ECU.

    2. A01JC31E07
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A22-33 (REQ+) - A22-32 (REQ-) Power switch off 80 to 170 Ω
    3. Connect the power management control ECU connector.


    NG
    OK
  14. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A22 from the power management control ECU.

    3. Disconnect connector A59 from the inverter with converter assembly.

    4. Turn the power switch on (IG).

    5. A01JBUZE06
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A22-24 (HTM+) - Body ground Power switch on (IG) Below 1 V
      A22-25 (HTM-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the connector of the power management control ECU and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A22-24 (HTM+) - A59-8 (HTM+) Power switch off Below 1 Ω
      A22-25 (HTM-) - A59-18 (HTM-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A22-24 (HTM+) or A59-8 (HTM+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A22-25 (HTM-) or A59-18 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
    8. Connect the inverter with converter assembly connector.

    9. Connect the power management control ECU connector.


    NG
    OK
  15. CHECK INVERTER WITH CONVERTER ASSEMBLY


    1. Disconnect connector A22 from the power management control ECU.

    2. A01JC31E08
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A22-24 (HTM+) - A22-25 (HTM-) Power switch off 80 to 170 Ω
    3. Connect the power management control ECU connector.


    NG
    OK
  16. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the inverter with converter assembly.

    3. A01JCYAE01

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      Bolt A
      T=20 N*m {204 kgf*cm, 15 ft.*lbf}
      Bolt B
      T=10 N*m {102 kgf*cm, 7 ft.*lbf}

      Note


      • Make sure that the tightening torque of the bolt A is between 16 and 24 N*m (163 and 245 kgf*cm, 12 and 18 ft.*lbf).

      • Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

    4. Disconnect the generator cable from the hybrid transaxle assembly.

    5. Check for arc marks at the bolts for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the hybrid transaxle assembly.

    7. Install the inverter with converter assembly.


    B
    C
    A
  17. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable.

    3. A01JAX5E01
      Text in Illustration
      *1

      Generator Cable

      (Inverter with Converter Assembly Side)

      *2 Shielded ground
      *3

      Generator Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      f1-2 (U) - f2-2 (U) Power switch off Below 1 Ω
      f1-3 (V) - f2-1 (V) Power switch off Below 1 Ω
      f1-1 (W) - f2-3 (W) Power switch off Below 1 Ω
      f1-2 (U) - f2-1 (V) Power switch off 100 MΩ or higher
      f1-3 (V) - f2-3 (W) Power switch off 100 MΩ or higher
      f1-1 (W) - f2-2 (U) Power switch off 100 MΩ or higher
    5. Install the generator cable.


    NG
    OK
  18. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01J8KC

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T=10 N*m {102 kgf*cm, 7 ft.*lbf}

      Note

      Make sure that the tightening torque of the bolts is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

    3. Disconnect the motor cable from the hybrid transaxle assembly.

    4. Check for arc marks at the bolts for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    5. Connect the motor cable to the hybrid transaxle assembly.


    B
    C
    A
  19. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the motor cable.

    3. A01JC5AE01
      Text in Illustration
      *1

      Motor Cable

      (Inverter with Converter Assembly Side)

      *2 Shielded ground
      *3

      Motor Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      e1-2 (U) - e2-3 (U) Power switch off Below 1 Ω
      e1-3 (V) - e2-2 (V) Power switch off Below 1 Ω
      e1-1 (W) - e2-1 (W) Power switch off Below 1 Ω
      e1-2 (U) - e2-2 (V) Power switch off 100 MΩ or higher
      e1-3 (V) - e2-1 (W) Power switch off 100 MΩ or higher
      e1-1 (W) - e2-3 (U) Power switch off 100 MΩ or higher
    5. Install the motor cable.


    NG
    OK