DESCRIPTION
Refer to the description for DTC P0C73-776 Click here.
The inverter water pump assembly sends the water pump speed (measured value) signal to the power management control ECU. When the power switch is on (READY), if the water pump speed (measured value) remains too low, this DTC is stored.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P314A | 828 | When either of the following conditions is met:
|
|
| DTC No. | INF Code | Data List Item |
|---|---|---|
| P314A | 828 |
|
*1: This Data List item is related to the inverter water pump assembly.
| DTC No. | INF Code | Active Test |
|---|---|---|
| P314A | 828 | Activate the Water Pump*2 |
*2: This is an Active Test of the inverter water pump assembly.
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0C73-776 Click here.
INSPECTION PROCEDURE
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 2 minutes or more.
PROCEDURE
CLEAR DTC
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
| NEXT |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the Activate the Water Pump Active Test.
Touch the inverter water pump assembly and check that it is operating (vibrating).
| OK |
|---|
| The water pump is operating (vibrating). |
Turn the power switch off.
| NG |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP) Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
Check the connections of the power management control ECU connectors.
| *1 | for LHD | *2 | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connection of the inverter water pump assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)
Disconnect connector A21 from the power management control ECU.
Disconnect connector g1 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
*2 | Front view of wire harness connector (to Inverter Water Pump Assembly) |
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Disconnect connector g1 from the inverter water pump assembly.
Turn the power switch on (IG).
| *1 | Component with harness connected (to Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Connect the inverter water pump assembly connector.
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| OK |
|
CLEAR DTC
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
| NEXT |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" Active Test.
| *a | Component with harness connected (Power Management Control ECU) |
Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.
| Item | Content |
|---|---|
| Terminal | A21-14 (NIWP) - L5-6 (E1) |
| Equipment Setting | 5 V/DIV., 100 ms./DIV. |
| Condition | Power switch on (IG), during Active Test |
| OK |
|---|
| The duration of wavelength A is 300 msec or less. |
Turn the power switch off.
| NG |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here |
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connection of the inverter water pump assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CHECK FUSE (IGCT NO. 3) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - IGCT RELAY)
Remove the IGCT relay from the engine room junction block assembly.
Disconnect connector g1 from the inverter water pump assembly.
While slightly shaking the wire harness, connector and engine room relay block and junction block assembly, measure the resistance according to the value(s) in the table below.
| *1 | Engine Room Relay Block and Junction Block Assembly | *2 | IGCT relay |
| *a | Front view of wire harness connector (to Inverter Water Pump Assembly) |
- | - |
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
Engine Room Relay Block and Junction Block Assembly
Apply slight vibration with a finger to the engine room relay block and junction block assembly and check whether a malfunction occurs.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Connect the inverter water pump assembly connector.
Install the IGCT relay.
| NG |
|
CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
Disconnect connector g1 from the inverter water pump assembly.
| *1 | Front view of wire harness connector (to Water Pump with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Junction Block Assembly |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the IGCT No. 3 fuse.
| NG |
|
CONNECT SECURELY Click here |
| OK |
|
CONNECT SECURELY (INVERTER WATER PUMP ASSEMBLY CONNECTOR))
CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE)
Check installation condition of the IGCT No. 3 fuse.
| OK |
|---|
| IGCT No. 3 fuse is installed correctly. |
| NG |
|
CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Remove the IGCT relay from the engine room relay block and junction block assembly.
Disconnect connector g1 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | Engine Room Relay Block and Junction Block Assembly | *2 | IGCT No. 3 Fuse |
| *3 | IGCT Relay | - | - |
| *a | Front view of wire harness connector (to Inverter Water Pump Assembly) |
- | - |
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Connect the inverter water pump assembly connector.
Install the IGCT relay.
Install the IGCT No. 3 fuse.
| NG |
|
CHECK FUSE (IGCT NO. 3) Click here |
| OK |
|
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Junction Block Assembly |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND) Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
Check the terminals of the IGCT No. 3 fuse holder.
| OK |
|---|
| The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded. |
| NG |
|
CHECK FUSE (IGCT NO. 3) Click here |
| OK |
|
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Junction Block Assembly |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE FUSE (IGCT NO. 3) |
| OK |
|
CONNECT SECURELY (IGCT NO. 3 FUSE)
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Junction Block Assembly |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS AND CONNECTOR Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
Disconnect connector g1 from the inverter water pump assembly.
| *1 | Front view of wire harness connector (to Water Pump with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS AND CONNECTOR Click here |
| OK |
|
CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
Check the terminals of the IGCT No. 3 fuse holder.
| OK |
|---|
| The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded. |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINAL) Click here |
| OK |
|
REPLACE INVERTER WATER PUMP ASSEMBLY
Replace the inverter water pump assembly Click here.
| NEXT |
|
REPLACE FUSE (IGCT NO. 3)
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Junction Block Assembly |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINAL) Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
CONNECT SECURELY
| NEXT |
|
REPLACE FUSE (IGCT NO. 3)
REPAIR OR REPLACE HARNESS AND CONNECTOR
| NEXT |
|
REPLACE FUSE (IGCT NO. 3)
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINAL)
| NEXT |
|
REPLACE FUSE (IGCT NO. 3)