HEATED OXYGEN SENSOR INSPECTION


  1. INSPECT HEATED OXYGEN SENSOR

    A01JBB9E01
    Text in Illustration
    *1

    Component without harness connected

    (Heated Oxygen Sensor)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      (HT) - (+B) 20°C (68°F) 11 to 16 Ω
      (HT) - (E) - 10 kΩ or higher

      If the result is not as specified, replace the heated oxygen sensor.