ECM INSTALLATION


  1. INSTALL ECM


    1. A01JAMF

      Install the ECM with the 2 bolts.

      Torque:
      13 N*m  { 133 kgf*cm, 10 ft.*lbf }
    2. A01J9T8

      Install the 2 wire harness clamps.

    3. Connect the 2 ECM connectors.


      1. A01JC7C

        Connect the 2 ECM connectors and lower the 2 levers.

        Note


        • When connecting the connectors, make sure that dirt, water or other foreign matter does not get caught between the connectors and other parts.

        • Make sure that the 2 levers are securely locked.

      2. Install the 2 wire harness clamps.

    4. A01JCP5

      Install the No. 2 engine room wire with the bolt.

      Torque:
      8.3 N*m  { 85 kgf*cm, 73 in.*lbf }
    5. A01JBFM

      Slide the side cover down and engage the 2 claws to install it.

    6. A01JD2W

      Slide the engine room wire harness down and engage the 2 claws to install it.

    7. A01JAY2

      Connect the 3 wire harness connectors.

    8. Install the No. 1 relay block cover.

  2. INSTALL RADIATOR WITHOUT CAP RESERVE TANK ASSEMBLY


    1. A01J8MD

      Install the radiator without cap reserve tank assembly with the 2 bolts.

      Torque:
      18 N*m  { 184 kgf*cm, 13 ft.*lbf }
  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  4. INSTALL REAR NO. 3 FLOOR BOARD


    1. A01JC33

      Engage the 2 guides to install the rear No. 3 floor board.

  5. INSTALL REAR DECK FLOOR BOX


    1. Install the rear deck floor box.

  6. INSTALL REAR NO. 2 FLOOR BOARD


    1. A01JCWRE01

      Engage the 3 guides <A>.

    2. Engage the 2 guides <B> and install the rear No. 2 floor board as shown in the illustration.

  7. PERFORM INITIALIZATION

    Tech Tips

    Initialization cannot be completed by only disconnecting and reconnecting the cable of the negative (-) battery terminal.


    1. Perform Initialization when replacing the ECM Click here.