SFI SYSTEM (w/ EGR System) VC Output Circuit

DESCRIPTION

The ECM constantly uses 5 V from the battery voltages supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.

A01JCNQE10

When the VC circuit is shorted, the microprocessor in the ECM and sensors that are supplied power through the VC circuit are inactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.

Tech Tips

Under normal conditions, the MIL is illuminated for several seconds when the power switch is first turned on (IG). The MIL goes off when the engine is started.

WIRING DIAGRAM

A01JCNSE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK MIL


    1. Check that the Malfunction Indicator Lamp (MIL) illuminates when turning the power switch on (IG).

      OK
      MIL lights up.

    NG
    OK
  2. CHECK CONNECTION BETWEEN INTELLIGENT TESTER AND ECM


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the tester on.

    4. Check the communication between the intelligent tester and ECM.

      Result
      Result Proceed to
      Communication is possible A
      Communication is not possible B

    A
    B
  3. CHECK MIL (THROTTLE POSITION SENSOR)


    1. Disconnect the throttle position sensor connector.

    2. Turn the power switch on (IG).

    3. Check the MIL.

      Result
      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the throttle position sensor connector.


    A
    B
  4. CHECK MIL (CAMSHAFT POSITION SENSOR)


    1. Disconnect the camshaft position sensor connector.

    2. Turn the power switch on (IG).

    3. Check the MIL.

      Result
      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the camshaft position sensor connector.


    A
    B
  5. CHECK MIL (MANIFOLD ABSOLUTE PRESSURE SENSOR)


    1. Disconnect the manifold absolute pressure sensor connector.

    2. Turn the power switch on (IG).

    3. Check the MIL.

      Result
      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the manifold absolute pressure sensor connector.


    A
    B
  6. CHECK HARNESS AND CONNECTOR (THROTTLE POSITION SENSOR - ECM)


    1. Disconnect the throttle position sensor connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      A01J950E26
      Standard Resistance
      Tester Connection Condition Specified Condition
      D28-88 (VCTA) or D4-5 (VC) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Throttle Position Sensor)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the throttle position sensor connector.

    5. Reconnect the ECM connector.


    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (CAMSHAFT POSITION SENSOR - ECM)


    1. Disconnect the camshaft position sensor connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      A01JC3BE44
      Standard Resistance
      Tester Connection Condition Specified Condition
      D18-3 (VC) or D28-99 (VCV1) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Camshaft Position Sensor)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the camshaft position sensor connector.

    5. Reconnect the ECM connector.


    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (MANIFOLD ABSOLUTE PRESSURE SENSOR - ECM)


    1. Disconnect the manifold absolute pressure sensor connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      A01JA2TE03
      Standard Resistance
      Tester Connection Condition Specified Condition
      D3-3 (VC) or D28-72 (VCPM) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Manifold Absolute Pressure Sensor)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the manifold absolute pressure sensor connector.

    5. Reconnect the ECM connector.


    NG
    OK