SFI SYSTEM (w/ EGR System), Diagnostic DTC:P0102, P0103

DTC Code DTC Name
P0102 Mass or Volume Air Flow Circuit Low Input
P0103 Mass or Volume Air Flow Circuit High Input

DESCRIPTION

The mass air flow meter sub-assembly is a sensor that measures the amount of air flowing through the throttle valve.

The ECM uses this information to determine the fuel injection time and to provide the appropriate air fuel ratio.

Inside the mass air flow meter sub-assembly, there is a heated platinum wire which is exposed to the flow of intake air by applying a specific electrical current to the wire.

The flow of incoming air cools both the wire and an internal thermistor, affecting their resistance. To maintain a constant temperature value of the hot wire, current is applied to these components in the mass air flow meter sub-assembly. The voltage level is proportional to the airflow through the sensor, and the ECM uses it to calculate the intake air volume.

The circuit is constructed so that the platinum hot wire and the temperature sensor create a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.

Tech Tips

When either of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine speed and throttle valve position. Fail-safe mode continues until a pass condition is detected.

A01JC8NE02
DTC No. DTC Detection Condition Trouble Area
P0102

Mass air flow meter voltage less than 0.2 V for 3 seconds

(1 trip detection logic)


  • Open or short in mass air flow meter sub-assembly circuit

  • Mass air flow meter sub-assembly

  • ECM

P0103

Mass air flow meter voltage more than 4.9 V for 3 seconds

(1 trip detection logic)


  • Open or short in mass air flow meter sub-assembly circuit

  • Mass air flow meter sub-assembly

  • ECM

Tech Tips

When any of these DTCs are set, check the air-flow rate by entering the following menus: Powertrain / Engine and ECT / Data List / MAF.

Mass Air Flow Rate (gm/sec) Malfunction
Approximately 0.0
  • Open in mass air flow meter sub-assembly power source circuit

  • Open or short in VG circuit

271.0 or more Open in E2G circuit

WIRING DIAGRAM

A01JC1ME03

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

PROCEDURE


  1. READ DTC OUTPUT


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / DTC.

    5. Read the DTCs.

      Result
      Result Proceed to
      DTC P0102 is output A
      DTC P0103 is output B

    B
    A
  2. INSPECT MASS AIR FLOW METER SUB-ASSEMBLY (POWER SOURCE VOLTAGE)

    A01JCAAE21
    Text in Illustration
    *1

    Front view of wire harness connector

    (to Mass Air Flow Meter Sub-assembly)


    1. Disconnect the mass air flow meter sub-assembly connector.

    2. Turn the power switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D5-3 (+B) - Body ground Power switch on (IG) 11 to 14 V
    4. Reconnect the mass air flow meter sub-assembly connector.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM)

    A01JAZYE33

    1. Disconnect the mass air flow meter sub-assembly connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      D5-5 (VG) - D28-94 (VG) Always Below 1 Ω
      D5-4 (E2G) - D28-117 (E2G)
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      D5-5 (VG) or D28-94 (VG) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Mass Air Flow Meter Sub-assembly)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the mass air flow meter sub-assembly connector.

    5. Reconnect the ECM connector.


    NG
    OK
  4. INSPECT MASS AIR FLOW METER SUB-ASSEMBLY

    A01JAJR

    1. Perform On-vehicle inspection Click here.

    2. Perform Inspection Click here.

    3. Inspect the function of the mass air flow meter sub-assembly.


      1. Remove the mass air flow meter sub-assembly with the connector connected.

      2. Connect the intelligent tester to the DLC3.

      3. Turn the power switch on (IG).

      4. Turn the tester on.

      5. Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.

      6. Blow air to the mass air flow meter sub-assembly and check that the intake air amount reading changes.

      OK
      The reading changes.

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (SENSOR GROUND)

    A01JCAAE22
    Text in Illustration
    *1

    Front view of wire harness connector

    (to Mass Air Flow Meter Sub-assembly)


    1. Disconnect the mass air flow meter meter sub-assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D5-4 (E2G) - Body ground Always Below 1 Ω
    3. Reconnect the mass air flow meter sub-assembly connector.


    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM)


    1. Disconnect the mass air flow meter sub-assembly connector.

      A01JAZYE34
    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      D5-4 (E2G) - D28-117 (E2G) Always Below 1 Ω
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Mass Air Flow Meter Sub-assembly)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the mass air flow meter sub-assembly connector.

    5. Reconnect the ECM connector.


    NG
    OK