ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System) INSTALLATION

Tech Tips


  • Use the same procedure for LHD and RHD vehicles.

  • The procedure listed below is for LHD vehicles.


  1. INSTALL ROOM TEMPERATURE SENSOR

    A003EBU

    1. Attach the 2 claws to install the sensor.

    2. Connect the connector and aspirator hose.

  2. INSTALL LOWER NO. 1 INSTRUMENT PANEL AIRBAG ASSEMBLY


    1. A00OIZC

      Connect the connector.

      Note

      When handling the airbag connector, take care not to damage the airbag wire harness.

    2. Attach the 2 claws to install the DLC3.

    3. Attach the 7 claws to install the instrument panel airbag.

    4. Install the 4 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
  3. INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY


    1. A00ONIX

      Attach the guide.

    2. Connect the connectors.

    3. A00OMHS

      Attach the claw to install the under cover.

    4. Install the 2 screws <A>.

  4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  5. CHECK SRS WARNING LIGHT


    1. Check the SRS warning light Click here.