AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) Back-up Power Source Circuit

DESCRIPTION

The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even after the ignition switch is turned off and is used for diagnostic trouble code memory, etc.

WIRING DIAGRAM

A003CILE02

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY)

    A003DM3E10
    Text in Illustration
    *1

    Rear view of wire harness connector

    (to Air Conditioning Amplifier Assembly)


    1. Disconnect the D101 amplifier connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      D101-21 (B) - Body ground Always 11 to 14 V

    NG
    OK