BACK-UP LIGHT SWITCH INSPECTION


  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY


    1. A002OX4E01

      Measure the resistance of the switch.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 Pushed Below 1 Ω
      1 - 2 Released 10 kΩ or higher

      If the result is not as specified, replace the back-up light switch assembly.