PURGE VALVE INSPECTION


  1. INSPECT PURGE VSV

    A005S7G

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω

      1 - VSV body

      2 - VSV body

      Always 10 MΩ or higher

      If the result is not as specified, replace the purge VSV.

    2. Check the operation of the purge VSV.


      1. A005SVBE01

        Check that air does not flow from port E to port F.

      2. A005TK4E01

        Apply battery voltage to the terminals as shown in the illustration.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.