DESCRIPTION
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| U1002 | Lost communication with the gateway module (power management bus). |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Tech Tips
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
PROCEDURE
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
Note
w/ Navigation System (for HDD):
After the ignition switch is turned off, the HDD navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the ignition switch off, wait a minute or more before disconnecting the cable from the negative (-) battery terminal.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
| NEXT |
|
CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU MAIN WIRE)
Disconnect the D75*1 or D104*2 power management control ECU connector.
*1: w/ Entry and Start System
*2: w/o Entry and Start System
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
| w/ Entry and Start System | ||||||
|
||||||
| w/o Entry and Start System | ||||||
|
| *1 | w/ Entry and Start System | *3 | Rear view of wire harness connector (to Power Management Control ECU) |
| *2 | w/o Entry and Start System | - | - |
| NG |
|
REPAIR OR REPLACE POWER MANAGEMENT CONTROL ECU MAIN WIRE OR CONNECTOR (CA3P, CA3N) |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY AND BODY GROUND)
Connect the cable to the negative (-) battery terminal.
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
Disconnect the D75*1 or D104*2 power management control ECU connector.
*1: w/ Entry and Start System
*2: w/o Entry and Start System
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| w/ Entry and Start System | |||||||||
|
|||||||||
| w/o Entry and Start System | |||||||||
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| w/ Entry and Start System | |||||||||
|
|||||||||
| w/o Entry and Start System | |||||||||
|
| *1 | w/ Entry and Start System | *3 | Rear view of wire harness connector (to Power Management Control ECU) |
| *2 | w/o Entry and Start System | - | - |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here