| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.394 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition |
|---|---|---|
| No. 1 cooling fan motor | 20°C (68°F) | 7.4 to 10.9 A |
| No. 2 cooling fan motor | 20°C (68°F) | 5.7 to 7.7 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator reservoir cap | Standard value (for brand-new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) | 78.5 kPa (0.8 kgf/cm2, 11.4 psi) |
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| No. 1 fan relay | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | ||
| No. 2 fan relay | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | ||
| No. 3 fan relay | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |