| Integration relay (EFI) |
1C-1 - 1B-4 |
Battery voltage not applied to terminals 1B- 2 and 1B-3 |
10 kΩ or higher |
| 1B-1 - 1B-4 |
| 1C-1 - 1B-4 |
Battery voltage applied to terminals 1B- 2 and 1B-3 |
Below 1 Ω |
| 1B-1 - 1B-4 |
| No. 1 integration relay (IG) |
3 - 5 |
Battery voltage not applied to terminals 1 and 2 |
10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 |
Below 1 Ω |
| No. 2 integration relay (IG2) |
1C-1 - 1A-4 |
Battery voltage not applied to terminals 1A- 2 and 1A-3 |
10 kΩ or higher |
| 1A-1 - 1A-4 |
| 1C-1 - 1A-4 |
Battery voltage applied to terminals 1A- 2 and 1A-3 |
Below 1 Ω |
| 1A-1 - 1A-4 |
| Circuit opening relay (C/OPN) |
DA-8 - DB-11 |
Battery voltage not applied to terminals DB-10 and DB-27 |
10 kΩ or higher |
| Battery voltage applied to terminals DB-10 and DB-27 |
Below 1 Ω |
| EFI injection relay (IGT/INJ) |
3 - 5 |
Battery voltage not applied to terminals 1 and 2 |
10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 |
Below 1 Ω |