BLOWER UNIT DISASSEMBLY


  1. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY


    1. A00443S

      Remove the 2 screws and recirculation damper servo sub-assembly.

  2. REMOVE AIR FILTER CASE


    1. A0041ZA

      Disengage the claw and guide, and remove the air filter case as shown in the illustration.

  3. REMOVE CLEAN AIR FILTER


    1. A0044C9

      Remove the clean air filter as shown in the illustration.

  4. REMOVE BLOWER WITH FAN MOTOR SUB-ASSEMBLY


    1. A004247

      Remove the 3 screws and blower with fan motor sub-assembly.

      Note

      Do not remove the blower with fan motor sub-assembly if it has been damaged or impacted.