AIR CONDITIONING SYSTEM, Diagnostic DTC:B1413/13

DTC Code DTC Name
B1413/13 Evaporator Temperature Sensor Circuit

DESCRIPTION

The evaporator temperature sensor is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the evaporator temperature sensor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temperature sensor and reads voltage changes as the resistance of the evaporator temperature sensor changes. This sensor is used for frost prevention.

DTC No. DTC Detection Condition Trouble Area
B1413/13 Open or short in evaporator temperature sensor circuit
  • Evaporator temperature sensor (No. 1 cooler thermistor)

  • Air conditioning harness assembly

  • Air conditioning amplifier assembly

WIRING DIAGRAM

A00403FE21

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Evaporator Fin Thermistor

      Evaporator temperature sensor (No. 1 cooler thermistor) /

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      OK
      The display is as specified in the Normal Condition column.
      Result
      Result Proceed to
      NG A
      OK (When troubleshooting according to Problem Symptoms Table) B
      OK (When troubleshooting according to the DTC) C

    B
    C
    A
  2. INSPECT EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)


    1. Remove the evaporator temperature sensor (No. 1 cooler thermistor) Click here.

    2. Disconnect the evaporator temperature sensor (No. 1 cooler thermistor) connector.

      A0040W9E01
      Text in Illustration
      *1 Sensing Portion *2 Resistance (kΩ)
      *3 Allowable Range *4 Temperature (°C (°F))
      *a

      Component without harness connected

      (Evaporator Temperature Sensor (No. 1 Cooler Thermistor))

      - -
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
      1 - 2 -5°C (23°F) 5.65 to 6.95 kΩ
      1 - 2 0°C (32°F) 4.40 to 5.35 kΩ
      1 - 2 5°C (41°F) 3.40 to 4.15 kΩ
      1 - 2 10°C (50°F) 2.70 to 3.25 kΩ
      1 - 2 15°C (59°F) 2.14 to 2.58 kΩ
      1 - 2 20°C (68°F) 1.71 to 2.05 kΩ
      1 - 2 25°C (77°F) 1.38 to 1.64 kΩ
      1 - 2 30°C (86°F) 1.11 to 1.32 kΩ

      Note


      • Hold the sensor only by its connector. Touching the sensor may change the resistance value.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).


    NG
    OK
  3. INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - EVAPORATOR TEMPERATURE SENSOR)


    1. Remove the air conditioning harness assembly Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      z11-6 (TEA) - 2 Always Below 1 Ω
      z11-5 (SGA) - 1 Always Below 1 Ω
      z11-6 (TEA) - Body ground Always 10 kΩ or higher
      z11-5 (SGA) - Body ground Always 10 kΩ or higher

    NG