LIGHT CONTROL RHEOSTAT INSPECTION


  1. INSPECT LIGHT CONTROL RHEOSTAT


    1. A003ZYAE13
      Text in Illustration
      *a

      Component without harness connected

      (Light Control Rheostat)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (E) - 3 (TR) Turn the light control rheostat knob fully downwards (MIN.) Below 50 Ω
      1 (E) - 3 (TR) Light control rheostat knob position is between MIN. and MAX. The value changes gradually (Between 0 to 12 kΩ
      1 (E) - 3 (TR) Turn the light control rheostat knob fully upwards (MAX.) 8 to 12 kΩ
      5 (TC) - 7 (T) Light control rheostat knob position is except below Below 50Ωr
      5 (TC) - 7 (T) Turn the light control rheostat knob fully upwards (Tail cancel switch is on) 8 to 12 kΩ

      If the value is not as specified, replace the light control rheostat.