INSPECT INTERIOR LIGHT CONTROL OPERATION
Note
When troubleshooting a function, first make sure that the function is set to the default setting.
Tech Tips
The interior light control illuminates the lights below.
Power Switch Illumination
Personal Light
Room Light
The operation and conditions of this control are described below.
| Operation | Operation Condition |
|---|---|
| Fade in and illuminate constantly | Any door is opened when all doors are closed. |
| Illuminate for 15 seconds, and then fade out | When any of the following conditions is met, the lights illuminate for 15 seconds, and then fade out.
|
| Fade out immediately | When any of the following conditions is met, the lights fade out immediately.
|
| Battery saver | When no changes occur in the condition of the doors for 20 minutes and a key is not in the actuation area, these lights turn off. |
Tech Tips
*1: When the lights are on, if the key leaves all of actuation areas around the doors, after approximately 3 seconds, the lights fade out.
INSPECT FOOTWELL LIGHT CONTROL OPERATION
Note
When troubleshooting a function, first make sure that the function is set to the default setting.
Tech Tips
The footwell light control illuminates the lights below.
Footwell light LH
Footwell light RH
The operation and conditions of this control are described below.
| Operation | Operation Condition |
|---|---|
| Fade in and illuminate constantly | When any of the following conditions is met, the footwell light LH and footwell light RH fade in.
|
| Illuminate for 15 seconds, and then fade out | When any of the following conditions is met, the footwell light LH and foot light RH illuminate for 15 seconds and then fade out.
|
| Fade out immediately | All doors are locked when the power switch is off, all doors are closed and any door is unlocked. |
| Dim | When the power switch is on (READY) and with park (P) selected, the shift lever is moved to select another shift state, the lights that operate dim. |
| Battery saver | When no changes occur in the condition of the doors for 20 minutes, the footwell lights turn off. |