INSPECT SECURITY INDICATOR LIGHT
| *a | Component with harness connected (Security Indicator Light (Combination Meter Assembly)) |
Apply auxiliary battery voltage from the wire harness back side between the specified terminals of the indicator, and check the lighting condition of the security indicator.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → Terminal 22 Auxiliary battery negative (-) → Terminal 30 |
Security indicator comes on |
If the result is not as specified, replace the No. 3 meter circuit plate.