THEFT DETERRENT SYSTEM Intrusion Sensor Cancel Switch Circuit

DESCRIPTION


WIRING DIAGRAM

A0040ZBE01

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING GTS (INTRUSION SENSOR CANCEL SWITCH)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Select the item below in the Data List and read the display on the GTS.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Intrusion Sens OFF SW Intrusion sensor cancel switch/ON or OFF

      ON: Intrusion sensor cancel switch on

      OFF: Intrusion sensor cancel switch off

      -
      OK
      The indicator on the GTS switches between ON and OFF in accordance with the intrusion sensor cancel switch status.

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) - MAP LIGHT ASSEMBLY)


    1. Disconnect the L8 main body ECU (multiplex network body ECU) connector.

    2. Disconnect the U3 map light assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L8-8 (SSW1) - U3-7 (SOFF) Always Below 1 Ω
      U3-1 (GND1) - Body ground Always Below 1 Ω
      L8-8 (SSW1) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT MAP LIGHT ASSEMBLY (INTRUSION SENSOR CANCEL SWITCH)


    1. A0042MBE02
      Text in Illustration
      *a

      Component without harness connected

      (Map Light Assembly (Intrusion Sensor Cancel Switch))

      Remove the map light assembly (intrusion sensor cancel switch) Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 7 Intrusion sensor on (intrusion sensor cancel switch not pressed) 10 kΩ or higher
      1 - 7 Intrusion sensor off (intrusion sensor cancel switch pressed) Below 1 Ω

    NG
    OK