RELAY ON-VEHICLE INSPECTION


  1. INSPECT FAN NO. 1 RELAY


    1. A00426O

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the fan relay.

  2. INSPECT FAN NO. 2 RELAY


    1. A003ZZ1

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Auxiliary battery voltage is not applied between terminals 1 and 2 Below 1 Ω
      3 - 4 Auxiliary battery voltage is applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the fan relay.

  3. INSPECT FAN NO. 3 RELAY


    1. A00426O

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the fan relay.