PURGE VALVE INSTALLATION


  1. INSTALL PURGE VSV


    1. A0040W8

      Install the purge VSV with the bolt.

      Torque:
      21 N*m  { 214 kgf*cm, 15 ft.*lbf }
    2. A0043D6

      Connect the 2 fuel vapor feed hoses and connector to the purge VSV.

  2. INSTALL AIR CLEANER CASE


    1. Install the air cleaner case with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
    2. Connect the No. 4 water by-pass hose to the air cleaner case with the 3 clamps.

    3. Install the air cleaner filter element.

  3. INSTALL INLET AIR CLEANER ASSEMBLY


    1. Install the inlet air cleaner assembly with the 2 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. Install the air cleaner cap sub-assembly with the 2 clamps and hose band.

    2. Connect the air flow meter connector.

  5. INSTALL NO. 2 CYLINDER HEAD COVER


    1. Engage the 3 clips to install the No. 2 cylinder head cover.

      Note


      • Be sure to engage the clips securely.

      • Do not apply excessive force or hit the cover to engage the clips. This may cause the cover to break.