WATER PUMP WITH MOTOR REMOVAL


  1. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    Click here.

  2. SEPARATE INVERTER RESERVE TANK ASSEMBLY


    1. A0042Y0

      Remove the 2 bolts, and separate the inverter reserve tank assembly.

  3. REMOVE INVERTER TRAY BRACKET


    1. A004126

      Separate the 2 clamps.

    2. Remove the 5 bolts and inverter tray bracket.

  4. REMOVE INVERTER WATER PUMP ASSEMBLY


    1. A0041TB

      Disconnect the 2 water hoses and connector.

      Note


      • Put pieces of cloth into the pipes and in the disconnected hoses to prevent foreign matter from entering the inverter water pump and cooling system.

      • Apply insulating tape to the connectors of the wire harness and inverter water pump assembly with motor to prevent the entry of coolant.

    2. A004027

      Remove the 3 bolts and the inverter water pump assembly with the water pump bracket.