| DTC Code | DTC Name |
|---|---|
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low |
DESCRIPTION
Refer to the description for DTC P1A40-123 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0B3D | 123 | Each battery block voltage becomes less than 2.8 V (open) (1 trip detection) |
Battery smart unit |
| P0B42 | |||
| P0B47 | |||
| P0B4C | |||
| P0B51 | |||
| P0B56 | |||
| P0B5B | |||
| P0B60 | |||
| P0B65 |
Tech Tips
Values smaller than 2.8 V may not be shown in the Data List because a fail-safe value is substituted.
Hybrid battery voltage sensor in the DTC titles refers to the battery smart unit.
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly or electric vehicle charger assembly, turn the power switch off. Also, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and electric vehicle charger assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Disconnect the GTS from the DLC3.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID BATTERY SYSTEM) Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Disconnect the GTS from the DLC3.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
REPLACE BATTERY SMART UNIT Click here