HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A78-306

DTC Code DTC Name
P0A78-306 Drive Motor "A" Inverter Performance

DESCRIPTION

For a description of the inverter Click here.

If the MG2 torque execution value does not correspond to the torque command value from the MG ECU to MG2, the power management control ECU will store this DTC.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A78 306 MG2 torque execution monitoring malfunction
  • Hybrid vehicle motor assembly

  • Motor cable

  • Inverter with converter assembly

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly or electric vehicle charger assembly, turn the power switch off. Also, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and electric vehicle charger assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      Only P0A78-306 is output, or DTCs other than the ones in the table below are also output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-202, 266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-203, 325, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
      P0AA6 (all INF codes)*1 Hybrid Battery Voltage System Isolation Fault
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-132 High Voltage Power Resource
      P3233-750 Open or Short to B+ in Blocking of HV Gate Connection

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A78-306 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


    B
    A
  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. A0043XQ

      Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

    2. Check the connection of the low voltage connector of the inverter with converter assembly.

      OK
      The connector is connected securely and there are no contact problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  3. CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A00446H

      Remove the inverter cover from the inverter with converter assembly.

    3. A0041WME01

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      Bolt A
      8.0 N*m (82 kgf*cm, 71 in.*lbf)
      Bolt B
      9.2 N*m (94 kgf*cm, 81 in.*lbf)

      Note


      • Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

      • Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).

    4. Disconnect the motor cable from the inverter with converter assembly.

    5. Check for arc marks at the bolts and terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the motor cable to the inverter with converter assembly.

    7. Install the inverter cover.


    B
    C
    A
  4. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A00446H

      Remove the inverter cover from the inverter with converter assembly.

    3. Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A0042RHE12
      Text in Illustration
      *1

      Motor Cable

      (Inverter with Converter Assembly Side)

      *2 Shield Ground

      Check MG2 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Condition Specified Condition
        e1-1 (W) - e1-2 (U) Power switch off 152.6 to 169.0 mΩ
        e1-2 (U) - e1-3 (V) Power switch off 157.6 to 174.0 mΩ
        e1-3 (V) - e1-1 (W) Power switch off 151.6 to 168.0 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68°F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Condition Specified Condition
      e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the inverter cover.


    NG
    OK
  5. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A0043ML

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      10 N*m (102 kgf*cm, 7 ft.*lbf)

      Note

      Make sure that the tightening torque of the bolts is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

    3. Disconnect the motor cable from the hybrid vehicle transaxle assembly.

    4. Check for arc marks at the bolts and terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    5. Connect the motor cable to the hybrid vehicle transaxle assembly.


    B
    C
    A
  6. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the motor cable.

    3. A004169E10
      Text in Illustration
      *1

      Motor Cable

      (Inverter with Converter Assembly Side)

      *2

      Motor Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      *3 Shield ground

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Condition Specified Condition
      e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      e1-1 (W) - e2-1 (W) Power switch off Below 1 Ω
      e1-2 (U) - e2-3 (U) Power switch off Below 1 Ω
      e1-3 (V) - e2-2 (V) Power switch off Below 1 Ω
      e1-1 (W) - e2-3 (U) Power switch off 100 MΩ or higher
      e1-2 (U) - e2-2 (V) Power switch off 100 MΩ or higher
      e1-3 (V) - e2-1 (W) Power switch off 100 MΩ or higher
    5. Install the motor cable.