INSTALL MOTOR CABLE
CAUTION:
Wear insulated gloves.
Install the motor cable to the hybrid transaxle assembly with the 3 bolts.
Note
Keep the sealing surface of the motor cable and the connector terminal joint free of foreign matter.
Engage the 2 claws to install a new terminal cap.
Note
When installing the terminal cap to the motor cable terminal block, keep the sealing surface free of foreign matter.
Do not pinch the O-ring.
Check that the terminal cap is securely installed.
Place the motor cable connector shell in position and install it with the 2 bolts.
Connect the 3 clamps.
INSTALL INVERTER TRAY BRACKET
Position the inverter tray bracket as shown in the illustration.
Temporarily install the inverter tray bracket with bolt B.
Tighten the 5 bolts to the inverter tray bracket in the following order: bolt A, bolt C, bolt D, bolt E and bolt B.
Connect the 2 clamps to the inverter tray bracket.
INSTALL INVERTER RESERVE TANK ASSEMBLY
Temporarily instal the inverter reserve tank assembly with bolt A.
Tighten the 2 bolts to the inverter reserve tank assembly in the following order: bolt B and bolt A.
INSTALL INVERTER WITH CONVERTER ASSEMBLY