MOTOR CABLE INSTALLATION


  1. INSTALL MOTOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. Install the motor cable to the hybrid transaxle assembly with the 3 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }

      Note

      Keep the sealing surface of the motor cable and the connector terminal joint free of foreign matter.

    2. Engage the 2 claws to install a new terminal cap.

      Note


      • When installing the terminal cap to the motor cable terminal block, keep the sealing surface free of foreign matter.

      • Do not pinch the O-ring.

      • Check that the terminal cap is securely installed.

    3. A0042EX

      Place the motor cable connector shell in position and install it with the 2 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    4. Connect the 3 clamps.

  2. INSTALL INVERTER TRAY BRACKET


    1. A004126E01

      Position the inverter tray bracket as shown in the illustration.

    2. Temporarily install the inverter tray bracket with bolt B.

    3. Tighten the 5 bolts to the inverter tray bracket in the following order: bolt A, bolt C, bolt D, bolt E and bolt B.

      Torque:
      18 N*m  { 184 kgf*cm, 13 ft.*lbf }
    4. Connect the 2 clamps to the inverter tray bracket.

  3. INSTALL INVERTER RESERVE TANK ASSEMBLY


    1. A0042Y0E01

      Temporarily instal the inverter reserve tank assembly with bolt A.

    2. Tighten the 2 bolts to the inverter reserve tank assembly in the following order: bolt B and bolt A.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
  4. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here