MOTOR CABLE REMOVAL


  1. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    Click here

  2. SEPARATE INVERTER RESERVE TANK ASSEMBLY


    1. A0042Y0

      Remove the 2 bolts, and separate the inverter reserve tank assembly.

  3. REMOVE INVERTER TRAY BRACKET


    1. A004126

      Separate the 2 clamps.

    2. Remove the 5 bolts and inverter tray bracket.

  4. REMOVE MOTOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. A0041HL

      Disconnect the 3 clamps.

    2. A00429S

      Remove the 2 bolts and slide the motor cable connector shell back.

    3. A00426G

      Disengage the 2 claws to remove the terminal cap from the hybrid transaxle assembly.

    4. A0043OB

      Remove the 3 bolts and motor cable from the hybrid transaxle assembly.