REMOVE INVERTER WITH CONVERTER ASSEMBLY
SEPARATE INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts, and separate the inverter reserve tank assembly.
REMOVE INVERTER TRAY BRACKET
Separate the 2 clamps.
Remove the 5 bolts and inverter tray bracket.
REMOVE MOTOR CABLE
CAUTION:
Wear insulated gloves.
Disconnect the 3 clamps.
Remove the 2 bolts and slide the motor cable connector shell back.
Disengage the 2 claws to remove the terminal cap from the hybrid transaxle assembly.
Remove the 3 bolts and motor cable from the hybrid transaxle assembly.