REMOVE NO. 1 ENGINE UNDER COVER
DRAIN COOLANT (for Engine)
Note
Do not remove the reservoir tank cap and radiator drain cock plug while the engine and radiator are still hot. Pressurized, hot engine coolant and steam may be released and cause serious burns.
Loosen the radiator drain cock plug.
Tech Tips
Collect the coolant in a container and dispose of it according to the local regulations.
Remove the reserve tank cap and drain the coolant.
| *1 | Reservoir Tank Cap | *2 | Radiator Drain Cock Plug |
REMOVE INVERTER WITH CONVERTER ASSEMBLY
SEPARATE INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts, and separate the inverter reserve tank assembly.
REMOVE INVERTER TRAY BRACKET
Separate the 2 clamps.
Remove the 5 bolts and inverter tray bracket.
REMOVE RADIATOR PIPE
Disconnect the clamps, No. 1 radiator hose, No. 4 water by-pass hose and No. 3 radiator hose.
Remove the 2 bolts and radiator pipe.
REMOVE GENERATOR CABLE
CAUTION:
Wear insulated gloves.
Disconnect the generator cable clamp from the motor cable bracket.
Remove the 3 bolts and slide the generator cable connector shell back.
Disengage the 2 claws to remove the terminal cap.
Remove the 3 bolts and generator cable from the hybrid transaxle assembly.