POWER WINDOW REGULATOR MOTOR INSPECTION


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Front LH)

    A01J3XJE01

    1. Apply battery voltage to connector terminals 1 and 2.

      Note

      Do not apply battery voltage to any terminals except terminals 1 and 2.

    2. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 1

      Battery negative (-) → 2

      Motor gear rotates counterclockwise

      Battery positive (+) → 2

      Battery negative (-) → 1

      Motor gear rotates clockwise

      • If the result is not as specified, replace the regulator motor assembly.

  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Front RH)

    A01J4UIE01

    1. Apply battery voltage to connector terminals 1 and 2.

      Note

      Do not apply battery voltage to any terminals except terminals 1 and 2.

    2. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 1

      Battery negative (-) → 2

      Motor gear rotates clockwise

      Battery positive (+) → 2

      Battery negative (-) → 1

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the regulator motor assembly.

  3. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Rear LH)

    A01J4S4E01

    1. Apply battery voltage to connector terminals 1 and 2.

    2. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 1

      Battery negative (-) → 2

      Motor gear rotates clockwise

      Battery positive (+) → 2

      Battery negative (-) → 1

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the regulator motor assembly.

  4. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Rear RH)

    A01J4XDE01

    1. Apply battery voltage to connector terminals 1 and 2.

    2. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 1

      Battery negative (-) → 2

      Motor gear rotates counterclockwise

      Battery positive (+) → 2

      Battery negative (-) → 1

      Motor gear rotates clockwise

      • If the result is not as specified, replace the regulator motor assembly.